- ページ 17
エアコンアクセサリー ActronAir ERQ5-24ASのPDF インストレーション&コミッショニング・マニュアルをオンラインで閲覧またはダウンロードできます。ActronAir ERQ5-24AS 20 ページ。 Esp platinum que split ducted unit - 3 phase
Installation and Commissioning Guide
11. Maximum Cable Lengths - Zoning
ZONE
OPTION 1
CAUTION
MEPS
MODEL
C E R T I F I E D
LIVE ELECTRICAL WIRING
R-410A
AUTHORISED TECHNICIANS ONLY
INTERNAL CONTROL ISOLATOR FITTED
A
OR
* All Zone Device Power Cable : Cat5E Spec Cables with RJ45 Connectors and Cable Boots - Green Colour
Item
1 to 2 and 1 to 3
1 to 8
4 to 8, 5 to 10
and 7 to 12
3 to 9 and 2 to 11
ActronAir is constantly seeking ways to improve the design of its products, therefore specifications are subject to change without notice.
INTEGRATED ZONE BARRELS
MODEL
(1-Zone Up To 8-Zone Options / Max. of 10 Zone Motors per System )
1
TOTAL CABLE LENGTH PER INDIVIDUAL ZONE (from 8-zone module) MUST NOT
R-410A
"CAUTION"
EXCEED 100 MTRS.
PLEASE
ENSURE
THERE IS
NO GAS / PRESSURE IN THE
FAN COIL UNIT BEFORE
REMOVING COPPER END CAPS.
3670-043
TOTAL LENGTH OF ALL ZONING CABLES (from 8-zone module) MUST NOT EXCEED
250 MTRS.
Zone Power Cable
Cat5E Spec Cables with RJ45 Connectors - Grey Colour
2
3
4
*
8
OR
1.5V
AAA
1.5V
AAA
8-zone module to 3-way cable joiner (P.N. 4070-012)
8-zone module to zone controller
zone barrel motor to zone device
3-way cable joiner to zone device
Copyright © 2019 Actron Engineering Pty. Ltd.
ESP Platinum QUE - Three Phase
ZONE
OPTION 2
5
*
*
9
10
1.5V
AAA
1.5V
AAA
1.5V
AAA
1.5V
AAA
TEMPERATURE
AVERAGING ZONE
1.5V
AAA
1.5V
AAA
Description
ZONE
OPTION 3
6
*
11
1.5V
AAA
1.5V
AAA
1.5V
AAA
1.5V
AAA
1.5V
AAA
1.5V
AAA
OR
AVERAGING ZONE
Maximum Cable Length
0.175m
100m
20m
20m
7
*
12
1.5V
AAA
1.5V
AAA
1.5V
AAA
1.5V
AAA
TEMPERATURE
1.5V
AAA
1.5V
AAA
17
1.5V
AAA
1.5V
AAA