SCOTCH–YOKE PART TURN PNEUMATIC ACTUATOR
GD2880 - GD8000 AND GS1440 - GS4000
j) Functional Safety
The ACTUATECH S.p.A. pneumatic actuators are also suitable for installations which require high level of functional reliability, up to
SIL3, in compliance with the IEC 61508 standard.
k) Marking and classification
All ACTUATECH actuators bodies are marked with the Manufacturer name and address, the actuator Type code including the Series
and Size, and its range of Pressure and Temperatures working conditions and limits.
Supplemental marking according to ATEX Directive (see section 8)
Marking instructions where the temperature is different from the standard one:
- low temperature version: T.min.= -50°C T.max= 60°C
- high temperature version: T.min.= -20°C T.max= 150°C
1. Name of the company in charge of marketing the product in the E.U.
2. Address of the company in charge of marketing the product in the E.U.
3. Model (with standard flanging), operating pressure and temperature.
4. ATEX class of compliance with the rules and level of protection.
5. Name of Technical File deposited with a Notified Body.
6. Product code.
7. Month and year of production.
ACTUATECH S.p.A
Via S. Lorenzo, 70, 25069 Villa Carcina (BS) Italy •
Ph.
+39 030 8908142 •
Fax
+39 030 8908143 • [email protected]