- ページ 16

産業機器 CAB WICON SQUIXのPDF サービスマニュアルをオンラインで閲覧またはダウンロードできます。CAB WICON SQUIX 18 ページ。 Wrap-around applicator

5

Error Treatment

16
i
Note!
The following table describes the reasons for error messages which occur repeatedly or permanently.
Message
Touch guard error
No label on belt
detected
Product release
failed/
Wrapping failed
Table 2
Error/Reasons
Failure of the touch guard movement
Shoulder screws at the guard plate
tightened to hard
Washers worn
Guard plate worn
Drive defective
Sensor touchguard defective
Cable sensor defective
PCB Control defective
After a labeling cycle is started no label is
detected on the transport belt
Label transfer from the printer failed
Transport module defective
PCB Spring Contact soiled
PCB Spring Contact defective
Contacts at the PCB Sensor Labels
worn
Sensor labels defective
PCB Control defective
Failure of the wrapping unit movement
Belt tension not correct
Chuck jaws hard-steering
Drive defective
Sensor Reference+Diameter defective
PCB Spring Contact soiled
PCB Spring Contact defective
Contacts at the PCB Sensor Labels
worn
PCB Control defective
Error treatment
Remedy
 Adjust the shoulder screws
 Replace the washers
 Replace the guide plate
 Replace the motor touchguard
 Replace the sensor touchguard
 Replace the cable sensor
 Replace the PCB Control
 Check the peel-off behavior
 Adjust the peel positions in the printer setup
and the software
 Replace the transport module
 Clean the contacts
 Replace the PCB Spring Contact
 Replace the PCB Sensor Labels
 Replace the PCB Sensor Labels
 Replace the PCB Control
 Adjust the belt tension
 Removing the winder plate and pulling-off the
cam plate
 Checking the movability of the chuck jaws in
the winder plate
 Replace the motor winder
 Replace the PCB Sensor Diameter
 Clean the contacts
 Replace the PCB Spring Contact
 Replace the PCB Sensor Labels
 Replace the PCB Control
16