- ページ 3

スイッチ CABAC HNS220TDのPDF オーナーズマニュアルをオンラインで閲覧またはダウンロードできます。CABAC HNS220TD 4 ページ。 Wall timer switch

5.3 SETTING THE TIMER
The Timer duration is set by configuring the Timer Range and Timer Settings switches.
• The Timer Range is determined by the positions of the Timer Range switches R1 and R2.
• The Timer Settings is determined by the sum of the values for each of the Timer Settings switches that are set
to ON (any combination of 8, 4, 2 and 1)
R1
OFF
ON
OFF
ON
The Timer duration is then calculated by the Timer Settings multiplied by the Timer Range.
For example, if 8,2 and 1 are ON, and the range R1 is OFF and R2 is ON, the timer duration will be
(8 + 2 + 1) x 10 minutes = 110 minutes ( 1 hour and 50 minutes )
5.4 APPLICATION EXAMPLE 1
10 minute timer, Power ON when timer is running, Indicator ON while power ON
• Set all switches to the OFF position
• Set the Load Output switch to the NO position to select the power ON during timer mode.
• Set the LED Indicator switch to the ON position to select the indicator on while power ON mode.
• Set the Timer Range to 1 minute ( 1 minute to 15 minutes possible duration ) switch R1 = ON, switch R2 = OFF
• Set the Timer Settings switches to add up to 10 ( 8 + 2 = 10 ), 10 x 1 minute = 10 minutes
5.5 APPLICATION EXAMPLE 2
7 hour timer, Power OFF when timer is running, Indicator ON while power OFF
• Set all switches to the OFF position
• Set the Load Output switch to the NC position to select the power OFF during timer mode.
• Set the LED Indicator switch to the OFF position to select the indicator OFF while power ON mode.
• Set the Timer Range to 1 hour with switch R1 = ON, switch R2 = ON
• Set the Timer Settings switches to add up to 7 ( 4 + 2 +1 = 7 ), 7 x 1 hour = 7 hours.
Customer Care Australia P: 133 122 F: 1300 303 310 E: [email protected] W:cabac.com.au
A: Distribution Pl, Seven Hills NSW 2147
Customer Care New Zealand P: 0800 966 969 F: 0088 6969 E: [email protected] W: cabac.co.nz
ADVANCED WALL TIMER SWITCH MANUAL
TIMER RANGE
R2
MULTIPLIER
OFF
10 seconds
OFF
1 minute
ON
10 minutes
ON
1 hour
LOAD
IND
TIMER
OUTPUT
LED
RANGE
NO
ON
R1
R2
NC
OFF
OFF
OFF
LOAD
IND
TIMER
OUTPUT
LED
RANGE
NO
ON
R1
R2
NC
OFF
OFF
OFF
TIMER SETTINGS (8, 4, 2 and 1)
MIN TIME SETTING
MAX TIME SETTING
10 seconds
1 minute
10 minutes
1 hour
TIMER
SETTINGS
8
4
2
1
OFF
OFF
OFF
OFF
TIMER
SETTINGS
8
4
2
1
OFF
OFF
OFF
OFF
2.5 minutes
15 minutes
2.5 hours
15 hour
CP13944 Rev 1, 19 MARCH, 2014
3