Automatic display on:
To automatically turn on the display when an active input is connected, slide the CEC
mode switch to the Auto position. When in Auto mode, the DL-AS31 will turn on the
display once an active source has been connected.
Automatic display off:
To automatically turn off the display when no active input is connected, slide the CEC
mode switch to the Auto position. When in Auto mode, the DL-AS31 will turn off the
display after no sources have been connected for three (3) minutes. To increase the
time before power off, send the
Manual display on/off:
To manually turn on or off the display, slide the CEC mode switch to the Man position.
When in Man mode, the DL-AS21C can turn on and off the display with active sources
connected to the inputs.
Contact Closure: Make a contact closure between the ON and GND contacts or the OFF
and ground contacts.
RS232: Transmit the
Display CEC Contact Closure Wiring
DL-AS31
L+
L-
R+
R-
Unbalanced Audio Connection
Display On/Off
CEC OFF XX
DISPLAY ON
DISPLAY OFF
or
Analog Audio Output Wiring
Audio
Device
L+
L
R
R+
command via RS232.
RS232 commands.
DL-AS31
L+
L-
R+
R-
Balanced Audio Connection
Audio
Device
L+
L-
R+
R-