- ページ 16

リピーター Argent Data Systems ADS-SR1のPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Argent Data Systems ADS-SR1 20 ページ。 Simplex repeater

Message Commands
##3<n> - Record Announcement
Records an announcement in the specified slot (0-9). If an announcement
already exists in the slot, the old message is erased and replaced. The repeater
will respond with an 'ok' beep. Transmit your message after the 'ok' beep, and
the repeater will respond by playing an 'ok' beep, followed by the message just
recorded.
Example: ##31- Record announcement 1
##2<n> - Play Announcement
Plays the specified announcement (0-9), or a 'negative' beep if the
announcement is blank.
Example: ##21 – Play announcement 1
##4<n> - Erase Announcement
Erases the specified announcement (0-9).
Example: ##41 –Erase announcement 1
##5<n><time> - Set Announcement Interval
If the interval for an announcement is not zero, it will be played
automatically at that interval. The time range can be from one second to twelve
hours. Default is zero (disabled).
Example: ##530100 – Set announcement 3 interval to 1 hour
##6<n><time> - Set Announcement Time Offset
Without the use of a time offset, all announcements with the same interval
would play at the same time. Use the offset to stagger messages. For example, to
alternate between messages 1 and 2 every five minutes, set both to interval 10,
and then set the offset for message 2 to 5 minutes. Message 1 will transmit at
00:00, message 2 at 00:05, message 1 again at 00:10, message 2 at 00:15, and so on.
Default is zero.
Example: ##6410 – Set announcement 4 offset to 10 minutes
15