- ページ 38

無線アクセスポイント Cisco ASR1006 - ASR 1006 Modular Expansion BaseのPDF ハードウェア・インストール・マニュアルをオンラインで閲覧またはダウンロードできます。Cisco ASR1006 - ASR 1006 Modular Expansion Base 47 ページ。 Lightweight access points
Cisco ASR1006 - ASR 1006 Modular Expansion Base にも: 配備マニュアル (40 ページ)

Cisco ASR1006 - ASR 1006 Modular Expansion Base ハードウェア・インストール・マニュアル
Step 1
Slip on the ESD-preventative wrist strap that was included in the accessory kit.
Before you turn off a power supply, make certain the chassis is grounded.
Step 2
Turn the power supply standby switch to the Standby position.of the power supply.
Step 3
Unplug the power cable from the AC inlet on the back of the power supply and the power source.
Step 4
Unscrew the power supply captive screws.
Step 5
Two power supplies must be installed in the chassis at all times to ensure sufficient cooling. The system fans are inside
Note
the power supply units and must spin for cooling. Because all the system fans can be powered by one power supply, the
second power supply unit does not have to be powered on, but it must be installed.
If you remove a power supply, the system can run for a maximum of five minutes before the system shuts down.
Caution
The fans and power elements are independent within the power supply. Therefore, it is not required that the
replacement power supply be energized within five minutes. The only requirement is that the power supply be
installed in the chassis, which energizes the fans and maintains proper system cooling.
Step 6
Grasping the power supply handles, pull the power supply from the chassis. When you remove the AC power supply,
you will see the following type of messages in the log report:
6ru_perf2#show log
Syslog logging: enabled (0 messages dropped, 6 messages rate-limited, 0 flushes, 0 overruns, xml
disabled, filtering disabled)
No Active Message Discriminator.
No Inactive Message Discriminator.
Console logging: disabled
Monitor logging: level debugging, 0 messages logged, xml disabled,
Buffer logging:
Exception Logging: size (4096 bytes)
Count and timestamp logging messages: disabled
Persistent logging: disabled
No active filter modules.
Trap logging: level informational, 78 message lines logged
Log Buffer (10000000 bytes):
*Jan 10 06:08:14.713: %CMRP-3-PEM_REMOVE_SHUT: R0/0: cmand:
*Jan 10 06:08:14.718: %ASR1000_PEM-6-REMPEM_FM: PEM/FM slot P1 removed
*Jan 10 06:08:28.966: %ASR1000_PEM-6-INSPEM_FM: PEM/FM slot P1 inserted
The second is after enabling console logging.
6ru_perf2#conf Configuring from terminal, memory, or network [terminal]?
Enter configuration commands, one per line.
6ru_perf2(config)#log con
% Ambiguous command:
6ru_perf2(config)#logg con
6ru_perf2(config)#^Z
6ru_perf2#
*Jan 10 06:08:54.643: %SYS-5-CONFIG_I: Configured from console by console
6ru_perf2#
38
filtering disabled
level debugging, 81 messages logged, xml disabled,
filtering disabled
"log con"
The system will shut down in 5 minutes
Output is at the console (and in the log).
End with CNTL/Z.