AUTO-DIAGNOSIS
LED
TIMER OPERATION STANDBY
N.
-
E1
E2
OO
E3
E4
O
E5
O
E6
E7
O
E8
E9
OO
OO = LED off
Definition of the LED lamps: Timer = YELLOW / Operation = GREEN / Standby = RED
INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH THE EUROPEAN DIRECTIVE
2012/19/EU
At the end of its working life this equipment must not be disposed of as an household waste.It must be taken to special local
community waste collection centres or to a dealer providing this service.Disposing of an electrical and electronic equipment
separately avoids possible negative effects on the environment and human health deriving from an inappropriate disposal
and enables its components to be recovered and recycled to obtain significant savings in energy and resources. In order to
underline the duty to dispose of this equipment separately, the product is marked with a crossed-out dustbin.
INFORMATION FOR CORRECT DISPOSAL OF THE BATTERY IN ACCORDANCE WITH THE EUROPEAN DIRECTIVE
2006/66/EC AND MODIFICATIONS INTRODUCED BY DIRECTIVE 56/2013/EU
Please replace battery when its electricity charge is used up: please do not eliminate this battery together with normal
household waste. It must be taken to special local community waste collection centres or to a dealer providing this service.
Disposing of a battery separately avoids possible negative effects on the environment and human health deriving from an
inappropriate disposal and enables its components to be recovered and recycled to obtain significant savings in energy and
resources. In order to underline the duty to dispose of this equipment separately, the battery is marked with a crossed-out
dustbin.
REGULATION (EU) No. 517/2014 - F-GAS
The unit contains R32, a fluorinated greenhouse gas with a global warming potential (GWP) of 675.
Do not release R32 into the atmosphere.
18
Heating mode not available
Communication error with HMI receiver PCB (WiFi model only)
Condensate drainage error (float error)
PFC error (over current, over voltage or PFC communication error)
O
Internal fan malfunction
Inverter PCB overtemperature (compressor module)
Compressor overcurrent
Defective or disconnected indoor air sensor (RAT)
O
Defective or disconnected coil sensor (ICT)
Defective or disconnected compressor discharge
temperature sensor (CDT)
= LED on
POSSIBLE CAUSE
= flashing LED
REMEDY
Select an available mode
Contact service centre
Contact service centre
Contact service centre
Contact service centre
Contact service centre
Contact service centre
Contact service centre
Contact service centre
Contact service centre