- ページ 7
ビデオカメラ Sony BRC-Z700 - CCTV CameraのPDF コマンドリストをオンラインで閲覧またはダウンロードできます。Sony BRC-Z700 - CCTV Camera 28 ページ。 Three 1/4-inch clearvid cmos ccd sensors hd robotic camera
Sony BRC-Z700 - CCTV Camera にも: パンフレット&スペック (8 ページ), 仕様 (8 ページ), パンフレット (8 ページ), パンフレット (8 ページ), クイックスタークマニュアル (2 ページ)
VISCA Command/ACK Protocol
Command
Command Message Reply Message
General Command
81 01 04 38 02 FF
(Example)
81 01 04 38 FF
(Example)
81 01 04 38 02 FF
(Example)
81 01 04 08 02 FF
(Example)
Inquiry Command
81 09 04 38 FF
(Example)
81 09 05 38 FF
(Example)
Address Set
88 30 01 FF
IF_Clear
88 01 00 01 FF
(Broadcast)
IF_Clear (For x)
8x 01 00 01 FF
Command Cancel
8x 2y FF
* When the camera address selector is set to an address other than 0, the value x in 88 30 0x FF will be variable.
Do not transmit the command (except Address Set,
IF_Clear, Command Cancel, CAM_Power) when any
menu is displayed on the screen. If displayed, clear the
menu first using CAM_Menu Command, and then
proceed.
Comments
90 41 FF (ACK)+90 51 FF
Returns ACK when a command has been accepted, or
(Completion)
Completion when a command has been executed.
90 42 FF
90 52 FF
90 60 02 FF
Accepted a command which is not supported or a command
(Syntax Error)
lacking parameters.
90 60 03 FF
Could not accept the command as there are two commands
(Command Buffer Full)
currently being executed.
90 61 41 FF
Could not execute the command in the current mode.
(Command Not Executable)
90 62 41 FF
90 50 02 FF (Completion) Does not return ACK.
90 60 02 FF
Accepted an incompatible command.
(Syntax Error)
88 30 02 FF
The device address number plus 1 is returned.*
88 01 00 01 FF
The same command is returned.
z0 50 FF (Completion)
ACK is not returned for this command.
z0 6y 04 FF
Returned when the command of the socket specified is
(Command Canceled)
canceled. Completion for the command canceled is not
returned.
z0 6y 05 FF
Returned when the command of the specified socket has
(No Socket)
already been completed or when the socket number specified
is wrong.
7