- ページ 12

ビデオカメラ Sony XCGH280EのPDF テクニカル・マニュアルをオンラインで閲覧またはダウンロードできます。Sony XCGH280E 46 ページ。 Digital video camera module
Sony XCGH280E にも: パンフレット (2 ページ)

Sony XCGH280E テクニカル・マニュアル

Trigger Edges and Width

When the camera is in Trigger Edge mode, it starts
shooting by detecting the rising or falling edge of a
trigger signal and performs shooting for the exposure
time specified in advance.
In Trigger Width mode, shooting is performed by
detecting the effective period of the trigger signal as the
exposure time.
Trigger Edge
Setting parameters: ExposureMode = Timed
Trigger signal
Exposure
Sensor output
Trigger Width
Setting parameter: ExposureMode = TriggerWidth
a
Trigger signal
Exposure
Sensor output

Special Trigger Modes

In a normal trigger operation, the settings, such as
exposure time, gain and imaging region, must be
changed in advance for each trigger input when shooting
under different conditions. Such setting changes can be
eliminated by activating a special trigger mode which
makes shooting under different conditions easier. Up to
16 configurations of camera settings can be used. There
are two types of special trigger modes: Bulk mode, in
which shooting continues after being started by a trigger
signal, and Sequential mode, in which shooting is
performed each time a trigger signal is detected. The
next exposure will start after the current image output is
completed. Therefore, the second and subsequent
trigger signal inputs in Sequential mode must be more
than 3 msec. after the end of the preceding image output.
Bulk mode
Setting parameters: TriggerMode = Off
For More Information Please Call Aegis Electronic Group, Inc. * (888) 687-6877 Phone * [email protected] * http://www.aegis-elec.com
12
TriggerActivation = RisingEdge/
FallingEdge ("FallingEdge"
selected in the figure below)
b
a
b
SpecialTriggerMode = Bulk
SpecialTriggerSource = Software/
Line3_TRIG1/Line4_TRIG2/
Line5_GPI1/Line6_GPI2/
Line3orLine4/Line3andLine4
SpecialTriggerActivation =
RisingEdge/FallingEdge
("FallingEdge" selected in the
figure below)
NumberOfMemoryForSpecialTrig
gerMode = 1 to 16 ("3" selected
in the figure below)
Trigger signal
Exposure
Sensor output
Setting 1
Sequential mode
Setting parameters: TriggerMode = Off
SpecialTriggerMode = Sequential
SpecialTriggerSource = Software/
Line3_TRIG1/Line4_TRIG2/
Line5_GPI1/Line6_GPI2/
Line3orLine4/Line3andLine4
SpecialTriggerActivation =
RisingEdge/FallingEdge
("FallingEdge" selected in the
figure below)
NumberOfMemoryForSpecialTrig
gerMode = 1 to 16 ("3" selected
in the figure below)
Trigger signal
Exposure
Sensor output
Setting 1
For Bulk and Sequential trigger modes, the following
function settings are read from the User Set memory and
reflected:
Image Format Control
• OffsetX
• OffsetY
Acquisition Control
• ExposureTime
Digital I/O Control
• LineInverter
• LineSource
• UserOutputValue
• StrobeActiveTime
• StrobeActiveDelay
Setting 2
Setting 3
Setting 2
Setting 3