- ページ 12

ネットワーク・ハードウェア Cisco 7609のPDF インストールをオンラインで閲覧またはダウンロードできます。Cisco 7609 22 ページ。 Internet router
Cisco 7609 にも: パンフレット (8 ページ), データシート (5 ページ), よくある質問 (5 ページ), ユーザーマニュアル (28 ページ)

Cisco 7609 インストール

System Ground Connection

System Ground Connection
Note
Note
Required Tools and Equipment
Note
Cisco 7609 Internet Router Installation Guide
3-12
This section describes how to connect a system (earth) ground to the Cisco 7609
Internet Router.
You must connect both the system ground connection and the power supply
ground connection to an earth ground. The system ground connection is
required if Foreign Exchange Station (FXS) modules are installed or if this
equipment is installed in a US or European Central Office.
Two threaded M4 holes are provided on the chassis frame to attach the ground
cable. (See
Figure
3-6.)
If FXS modules are installed or if this equipment is installed in a US or
European Central Office, you must use the system (earth) ground on both AC-
and DC-powered systems.
To connect the system ground, you need the following tools and materials:
Materials are not provided; contact any commercial cable vendor for the
required parts.
Grounding lug
The grounding lug must have two M4 screw holes and accept 6 AWG wire.
Two M4 (metric) hex-head screws with locking washers
One grounding wire
The grounding wire should be sized according to local and national
installation requirements. The length of the grounding wires depends on the
proximity of the Cisco 7609 Internet Router to proper grounding facilities.
Number 2 Phillips-head screwdriver
Crimping tool
Chapter 3
Installing the Cisco 7609 Internet Router
OL-5079-04