- ページ 7

デジタルカメラ Sony NEX-VG30HのPDF サービスマニュアルをオンラインで閲覧またはダウンロードできます。Sony NEX-VG30H 32 ページ。 Interchangeable lens digital hd video camera recorder
Sony NEX-VG30H にも: 限定保証 (1 ページ), 仕様 (4 ページ)

Sony NEX-VG30H サービスマニュアル
1-5. PRECAUTION ON REPLACING THE MB N PLATE
Perform the following procedures for each of the three washers.
Note: Measure the dimensions before replacement of the MB N Plate according to procedures (1) to (3).
(1) Remove the Imager Block Assy and the IM Adjust Washers.
(2) Measure the dimensions (A) of the removed IM Adjust Washers.
(3) Measure the distance (B) between the surface of the screw hole where the IM Adjust Washers were set and the surface of the E-Mount.
(4) Likewise, measure the dimensions (B') of each location where IM Adjust Washers of new Cabinet Front are installed.
(5) Calculate the dimension of (A') of new IM Adjust Washers by using the formula below, and select the washers.
Dimension (A+B) before replacement – Dimension (B') of new Cabinet Front
= Dimension (A') of IM Adjust Washer after replacement
(6) Assemble the imager, using the selected IM Adjust Washers.
(7) After assembling is completed, perform the test shooting and confirm that no blur is observed in the peripheral area of shot.
NEX-VG30/VG30E/VG30EH/VG30H_L2
SSM height adjustment
measurement JIG
1-3

1-6. SELF-DIAGNOSIS FUNCTION

1-6-1. Self-diagnosis Function
When problems occur while the unit is operating, the self-diagnosis
function starts working, and displays on the LCD screen what to do.
This function consists of two display; self-diagnosis display and service
mode display.Details of the self-diagnosis functions are provided in the
Instruction manual.
LCD screen
Blinks at 3.2 Hz
C
3 2
0 0
Repaired by:
Block
C : Corrected by customer
Indicates the appropriate
Refer to "1-6-3. Self-diagnosis Code Table".
E : Corrected by service
step to be taken.
engineer
E.g.
13 ....Format the "memory card".
32 ....Turn on power again.
1-6-3. Self-diagnosis Code Table
Self-diagnosis Code
Symptom/State
Block
Detailed
Function
Code
C
0
4
0
0
Non-standard battery is used.
C
0
6
0
0
The battery pack temperature is high.
Memory card is unformatted.
C
1
3
0
1
Memory card is broken.
C
1
3
0
2
Access error
C
1
3
0
3
Access error (External media)
C
1
3
0
4
Drive fault (External media)
C
3
2
6
0
*
Difficult to adjust focus
(
*
)
E
6
1
0
0
(Cannot initialize focus)
E
2
0
0
0
Flash memory data are rewritten.
E
3
1
0
0
Drive fault
Note 1: Start the Adjust Manual in the Adjust Station and refer to the "DESTINATION DATA WRITE".
Note 2: Functions of codes with * mark are not provided in this unit.
1-6-2. Self-diagnosis Display
When problems occur while the unit is operating, the counter of the LCD
screen shows a 4-digit display consisting of an alphabet and numbers,
which blinks at 3.2 Hz. This 5-character display indicates the "repaired
by:", "block" in which the problem occurred, and "detailed code"of the
problem.
Detailed Code
Correction
Use the InfoLITHIUM battery.
Change the battery pack or place it in a cool place.
Format the memory card.
Insert a new memory card.
Remove the power source. Reconnect it again and operate your cam-
corder again.
Turn power off and turn power on again.
Turn power off and turn power on again.
Turn power off and turn power on again.
Make flash memory data correct value. (Note 1)
Turn power off and turn power on again.
– ENGLISH –