- ページ 21

デジタルカメラ Sony XCL-CG510CのPDF テクニカル・マニュアルをオンラインで閲覧またはダウンロードできます。Sony XCL-CG510C 48 ページ。 Digital video camera module

Special trigger

When operating in trigger mode and performing image pickup in different conditions (such as the shutter, gain, and
image pickup area), the setting has to be changed in advance for each trigger input. However, if the special trigger
operation is enabled, the setting does not have to be changed and continuous image pick up in different conditions is
facilitated. Up to 16 settings can be configured. There are the bulk operations in which images are taken consecutively
by inputting the trigger signal once and the sequential operation in which images are taken each time the trigger signal
is detected. The next exposure is started after the end of video output. In the sequential operation, the second and
subsequent trigger signals should be input 5 ms or more after the end of video output. During the special trigger
operation, the device cannot be entered to the trigger mode. The source and polarity of the special trigger signal should
be defined separately from the trigger mode. Each setting should be saved in the user set. For the items reflected, refer
to "Command List" (page 38).
Note
During special trigger operation, defect correction cannot be used.
Command
Parameter
SP-TRG-MODE
0
1
2
Command
Parameter
SP-TRG-SRC
4
7
10
11
101
102
103
104
0
20
Command
Parameter
SP-TRG-POL
0
1
Setting
Special trigger off
Bulk
Sequential
Setting
DC power input connector 4th pin (GPI1)
DC power input connector 7th pin (GPI3)
DC power input connector 10th pin (GPI4)
DC power input connector 11th pin (GPI2)
DIGITAL Interface connector 22nd [+]/9th [-] (CC1)
DIGITAL Interface connector 10th [+]/23rd [-] (CC2)
DIGITAL Interface connector 24th [+]/11th [-] (CC3)
DIGITAL Interface connector 12th [+]/25th [-] (CC4)
Software command (TRG-SOFT)
OR of GPI1/GPI2/GPI3/GPI4
Setting
Negative
Positive
21