デジタルカメラ Sony XCU-CG160CのPDF テクニカル・マニュアルをオンラインで閲覧またはダウンロードできます。Sony XCU-CG160C 45 ページ。 Digital video camera module
Trigger width detection (ExposureMode = TriggerWidth)
BurstFrameCount = 7
BurstTriggerMode=DualExposureMode
T
Trigger signal
Exposure
T
Trigger states
Free run
Trigger mode
Trigger inhibit
Trigger input can be disabled. This function is effective when disabling the trigger signal to a specific camera in an
environment where multiple cameras are triggered by the same trigger signal, and when preventing false operations
caused by noise on the trigger signal line (due to the installed environment).
Trigger signal
Trigger inhibition
Exposure
Sensor output
Feature
Parameter
TriggerInhibit
False (0)
True (1)
T × Exposure2Ratio
T
T × Exposure2Ratio
BurstTriggerMode
2
Setting
Trigger is accepted
Trigger is not accepted
T
T × Exposure2Ratio
Off (normal trigger)
ExposureMode
SingleExposureMode
ExposureMode
DualExposureMode
ExposureMode
Trigger
disabled
19
T
Trigger edge detection
Trigger width detection
Trigger edge detection
Trigger width detection
Trigger edge detection
Trigger width detection