DPC Active LED States
Color
None
DPC Active LED States
The Active LED on the DDPC/UDPCPC or /DPC2/UDPC2 indicates that the software is loaded on the card
and that the card is ready for operation. When the system first boots up, all installed DPC/UDPCs or
/DPC2/UDPC2s are booted into standby mode. The system must then be configured as to which DPC/UDPCs
or /DPC2/UDPC2s should serve as redundant components (remain in standby mode) and which should function
as active components.
The possible states for this LED are described in the following table. If the LED is not green, use the
troubleshooting information in the table to diagnose the problem.
Table 10: DPC Active LED States
Color
Green
Blinking Green
Troubleshooting
10
Description
Card is not receiving power.
Description
Card is active.
Tasks or processes are being migrated from
an active DPC to a standby DPC.
Troubleshooting
Troubleshooting
Verify that the LEDs on the PFUs are blue.
If they are not, refer to
Checking the LEDs
on the PFU, on page 2
for troubleshooting
information.
Verify that the power source is supplying
ample voltage and current to the chassis.
Verify that the card is properly installed
and licensed per the instructions in the ASR
5500 Installation Guide.
If all of the above suggestions have been
verified, it is possible that the DPC/UDPC
or /DPC2/UDPC2 is not functional. Please
contact your service representative.
Troubleshooting
The first time power is applied to the
system, all of the DPC/UDPCs or
/DPC2/UDPC2s should be booted into the
standby mode. Therefore, this LED should
be off.
Verify that the Redundancy LED on a
standby DPC/UDPC or /DPC2/UDPC2 is
also blinking green. If so, there is an issue
with the active DPC/UDPC or
/DPC2/UDPC2 and it is transferring its
processes.
Refer to Monitoring the System for
information on determining the status of
the DPC/UDPC or /DPC2/UDPC2 and
system software processes and
functionality.