- ページ 5

コントローラー Digitrax DZ123MK0のPDF クイック・スタート・マニュアルをオンラインで閲覧またはダウンロードできます。Digitrax DZ123MK0 8 ページ。 Complete train control

Digitrax DZ123MK0 クイック・スタート・マニュアル
speed Tables-How the Loco Responds to the Throttle
With Digitrax LocoMotion
and High Resolution 28 Step Tables. Please see your Decoder Manual for a
discussion of the 28 Step Tables. The 3 Step Tables are set up by programming 3
CVs: Start Voltage (CV02), Mid point Voltage (CV06) and Max Voltage
(CV05). These values are set at 000 at the factory. All have a range of values
from 000 to 255. We recommend the following CV values as a starting point for
experimenting with speed tables.
Loco Type
Switcher
Concentrated low speed. Limited top
speed
Road Switcher
Prototypical top speed w/evenly
distributed curve from 0 to top speed
Mainline Loco
Quick increase to cruising speed then
levels off to prototypical top speed.
other LocoMotion
Travel & scaleable speed stabilization (Back eMF) Features
Switching speed is controlled by CV54. The factory setting is 000 for OFF. To
turn on the switching speed feature, program CV54 to a value of 001. When
this feature is on, use F6 to activate and deactivate switching speed. With the
feature on the throttle's target speed is effectively reduced by about 50% and
the effects of accel and decel programmed into the decoder are reduced by 1/4.
This is useful for yard switching operations.
Normal Direction of Travel is controlled by CV29. See your decoder manual
for additional information on the settings for CV29.
©2012 Digitrax, Inc
2443 Transmitter Rd
Panama City, FL usA 32404
www.digitrax.com
®
, there are two types of speed tables: 3 Step Tables
Features: switching speed, Normal Direction of
®
www.digitrax.com
suPPoRT
RePAIR
V Start
V Mid
CV02
CV06
002
038
002
048
002
128
V Max
CV05
064
098
154
5