Cisco Nexus 7000 Series トラブルシューティングマニュアル
Troubleshooting
Step 3
Make sure that the fabric module is properly seated in the chassis as follows:
a) Loosen the captive screws on the fabric module until they are no longer in the chassis.
b) Press the eject buttons on either end of the module and simultaneously rotate out both ejector levers until the module
is unseated from the midplane.
c) Place one hand on the module handle and pull the module part way out of the chassis.
d) Push the module back into the chassis until it is seated on the midplane.
e) Simultaneously rotate both ejector levers until they both touch the front of the module. This action fully seats the
module on the midplane.
f) Make sure that each of the captive screws on the module is aligned with its holes in the chassis.
g) Screw in each captive screw to the chassis and tighten to 8 in-lb (0.9 N·m).
Step 4
Contact TAC for assistance (see the

Troubleshooting the I/O Modules

The following conditions indicate that there are problems with one or more I/O modules:
• The IOM LED on the chassis is amber.
• The STATUS LED on an I/O module is red.
During initialization, the STATUS LED is amber while the I/O module powers up and performs diagnostic
tests. When the diagnostic tests are complete, the STATUS LED becomes green. If an overtemperature
condition occurs, the STATUS LED becomes amber. If the module is resetting, ejectors are out, or if there is
a major overtemperature condition, the LED flashes red.
For a listing of the I/O module LEDs and the conditions that they indicate, see
To troubleshoot an I/O module hardware problem, follow these steps until the problem is resolved:
SUMMARY STEPS
1. Determine which I/O module has a problem. Check if a STATUS LED that is flashing red or is not lit on
a module.
2. Check if the power supply units are providing power to the chassis components. See the
the Fan Trays, on page
3. Make sure that the I/O module is properly seated in the chassis by following these steps:
4. Contact TAC for assistance (see the
DETAILED STEPS
Step 1
Determine which I/O module has a problem. Check if a STATUS LED that is flashing red or is not lit on a module.
Step 2
Check if the power supply units are providing power to the chassis components. See the
on page
2.
Step 3
Make sure that the I/O module is properly seated in the chassis by following these steps:
a) Loosen the captive screws on the I/O module until they are no longer in the chassis.
b) Press the eject buttons on either end of the module.
c) Simultaneously rotate out both ejector levers until the module is unseated from the midplane.
Contacting Customer Service, on page
2.
Contacting Customer Service, on page
Troubleshooting the I/O Modules
10).
Table D-3 on page D-4
Troubleshooting
10).
Troubleshooting the Fan Trays,
Troubleshooting
.