2.2.7 Removal of Pulley Set and Pressure Spring

1.
Remove the Timing Belt from the Pulley Set. (Refer to Step 9 in the Removal of
Carriage Unit.)
2.
Insert the flat-blade screwdriver into the engagement of the Pulley Set and Pressure
Spring, and remove the Pressure Spring.
When removing the Pulley Set/Pressure Spring, fully be careful not to
C A U T I O N
push the Pressure Spring too much since the Pressure Spring may pop
out.
3.
Slide the Pulley Set to the rear, and remove it from the Lower Housing.
DISASSEMBLY/ASSEMBLY
Flat-blade screwdriver
Engagement
Pulley Set
Disassembly Procedure
Pressure Spring
Figure 2-24. Removal of Pressure Spring
Step 3-2)
Step 3-1)
Figure 2-25. Removal of Pulley Set
Revision B