CONTROLLER SETTINGS

Control Terminals
OPN ----- N/O open input.
PED ------ N/O pedestrian open push button, only open motor-1
PEB ------ N/C photo electrical beams
OSC------ N/O Open – Stop – Close--Open
OL1 ------ Motor 1 open limit switch, N/C or N/O selected by DIP4
CL1 ------ Motor 1 close limit switch, N/C or N/O selected by DIP4
OL2 ------ Motor 2 open limit switch, N/C or N/O selected by DIP4
CL2 ------ Motor 2 close limit switch, N/C or N/O selected by DIP4
Buttons
OPN button ---- Full (M1&M2) open gate and used for settings
PED button ----- Ped (M1) open gate and used for settings
CLS button ----- CLS gate and used for settings
OSC button ----- Open – Stop – Close—Open and for setting
3.2 DIP Switch Settings
DIP1---- SET
ON—set,
DIP2---- SYNC
ON—SYNC mode,
DIP3---- DIP3
Spare for V4.2 and before
ON—Encoder control M1 only, OFF – limit control
DIP4---- CODE
DIP5---- LKPS
ON—Lock Pulse Output,
DIP6---- NOLS
ON—N/O limit switch,
DIP7---- PECL
ON—PE trig Auto Close,
DIP8---- AUCL
ON—Auto Close Mode,
3.3 Motor Force
If any motor current over current setting, both motors will stop in opening cycle or reopen in
closing.
If gate(motor) already in low-speed section and nearly closed or opened, controller will not
response the overload
3.4 Power input
12 or 24V AC power input. 12VAC for 12VDC motor, 24VAC for 24V DC motor
3.5 Battery Backup
12V battery --- 12VDC motor, 12VAC input.
24V battery --- 24VDC motor, 24VAC input.
Solar regulator output can be direct connected to this terminal if in case of solar application.
3.6 Motor output
M1: Motor 1 output. M2: Motor 2 output
3.7 Power output
Power out for accessaries. About 14V----- 12VAC supply, about 26V------24VAC supply
3.8 Timers setting
Push Buttons functions
Button
SET ON---Setting
OPN
Sync Delay Time
PED
Lock Pulse Time
CLS
PE Trig Close Time
STP
Auto Close Time
OFF – Run
OFF – No Sync mode
OFF – Lock Presence Output
OFF – N/C limit switch
OFF – No PE trig Auto close
OFF – No Auto close
SET OFF---Running
Open gate
Lock pulse Time
PE Trig Close Time
Auto Close Time
- 11 -
Note