Terminal Block Connections
Terminal 1 - Marked "+" (+12V) - Connect to a positive Voltage of 9.6 -16Vdc source
(Usually from the alarm CP)
Terminal 2 - Marked "-" (GND) - Connect to the ground of the CP.
Terminal 3 –Marked "Test" 9.6-16 v on this pin will enter the EDS2000AM to walk test
mode even if SW2 position 1 is off
Terminals 4 & 5 - Marked "ALARM" - These are the output relay contacts of the detector.
Connect to a normally closed or normally opened zone in the control unit. When an
intruder is detected, alarm relays (N.C. and N.O.) will switch for 1.8 sec.
Terminal 6&7 - Marked "AM/FAIL" These are the output of the anti mask and Trouble relay
(N.C. and N.O.) Will switch if one from the following scenario happens:
The supply voltage is under 8.5v
Mask detection (will restore if the mask is removed)
PIR or MW self test fail (every 10 hours the detector made self test for PIR and MW
sensors)
Terminal 8 - Marked "TEOL" - End of line – optional terminal for end of line resistors
connections.
Terminals 10 & 9 - Marked "TAMPER" - If a Tamper function is required connect these
terminals to a 24-hour normally closed protective zone in the CP.
If the top cover of the detector is opened or the detector is detached from installation wall,
an immediate alarm signal will be sent to the CP.
7.1 Wire Size Requirements
Use #22 AWG or larger wires. Use the following table to determine required wire gauge
and length.
P/N: 7101796A
Wire Length [m]
Wire Length [ft.]
Wire Gauge [#]
205
310
510
800
1200
2000
22
20
18
870
3400
16