- ページ 12

換気フード diLUSSO TH619DSLのPDF ユーザーマニュアルと設置手順をオンラインで閲覧またはダウンロードできます。diLUSSO TH619DSL 16 ページ。 Telescopic hood

Installation

To fix the rangehood to the kitchen unit.
The lower part of the hood must be located at a minimum height of 70cm
above the hob for electric and gas cookers. If the instructions of a gas cooker
indicate a greater distance these must be observed.
When the rangehood is working at the same time as other non-electrical
cooking equipment, the outlet air pressure must not exceed 4 Pa.
To achieve optimum performance the length of the outlet hose should not
exceed 4 meters, or include more than two 90 angles (elbows)
Drill a hole of 140mm diameter for hood outlet, 4*Ø8mm mounting holes and
one clearance for power cord on the cabinet board referring to the following :
Insert 4 mounting screws with 4 mounting gaskets to fix the hood.
12