RADIO CALLS
REPEATER OR TALKAROUND
MODE
Talkaround Mode enables you to communicate with
another radio when either:
•
the repeater is not operating
—or—
•
your radio is out of the repeater's range but
within communicating distance of another radio.
Press the preprogrammed Repeater/Talkaround
button to toggle between Repeater mode and
Talkaround Mode.
SETTING TIGHT OR NORMAL
SQUELCH
Use this feature to filter out nuisance (unwanted)
calls and/or background noise. However, tightening
squelch could cause calls from remote locations to
be filtered out as well. In this case, normal squelch
may be more desirable.
Press the preprogrammed Squelch button to toggle
between tight and normal squelch.
English
14
SETTING THE POWER LEVEL
Each channel in your radio has a predefined
transmit power level that can be changed.
•
High power allows you to reach a radio that is
farther away.
•
Low power conserves the battery's charge.
Press the preprogrammed Power Level button to
toggle between low and high power.
RECEIVING A SELECTIVE CALL
When you receive a selective call:
•
The LED indicator flashes yellow, if programmed
by your dealer.
•
You hear two high pitched tones.
To answer the call, press the PTT button.
RECEIVING A CALL ALERT PAGE
When you receive a Call Alert Page:
•
The LED indicator flashes yellow, if programmed
by your dealer.
•
You hear four high pitched tones.
To answer the Page, press the PTT button; to
cancel the Page, press any other key.