デスクトップ Epson EL 3S/33のPDF 製品サポート速報をオンラインで閲覧またはダウンロードできます。Epson EL 3S/33 1 ページ。 Product support bulletin(s)
Epson EL 3S/33 にも: 製品情報マニュアル (9 ページ)
VER
PART #
1.11.1.12
1.11.1.12
1.13.1.14
201311201
1.13.1.14
201311301
VER
PART #
1.03
930219
EPSON NX
DESC
TYPE
SYSTEM
27C010
SETUP
27C512
SYSTEM
27C010
SETUP
27C512
EL3S/33
DESC
TYPE
PHOENIX
27C010
PSB No.: S-0062I
Page: 1 of 18
LOC
REASON
U1
INITIAL RELEASE
U113
U1
Corrected jagged cursor display in
U113
interlaced mode with the BT-482
RAMDAC when using the hardware
cursor Wingine display drivers.
Serial BIOS has been expanded to
support COM3 and COM4. Parallel
BIOS has been corrected to provide
support for LPT1-LPT3. Corrected
inability to run SETUP when an
adaptec AHA-1540C or 1542C SCSI
host adapter is installed by modifying
POD to run external ROM
initialization routines just prior to
invocation of SETUP. Corrected
timing of parallel port STROBE signal
to allow for slow rise time and longer
cable lengths. Removed internal
cache test. The cache test failed,
regardless of cache condition. Since
the 80486 CPU perform internal
cache testing at power-up, disabling
the POD cache test will not affect
system performance. (SEE ECN
NO: PROG4-002) 12/03/93.
LOC
REASON
U19
INITIAL RELEASE