(36)Parameter Configuration Flow Chart
Level 1
Main output
Percentage
Range=0~100%
Aux. output
percentage
Range=0~100%
Alarm 1 Low value
Range=0~99
℃/℉
Alarm 1 Hi value
℃/℉
Range=0~99
Alarm 2 value
Range=0~99
℃/℉
PID auto tuning
:none
:Execute once
:execute every
times
auto tuning switch
Yes:start AT tuning
NO:stop AT tuning
Take 6 :
If the Main O/P control
model(
) set to
mode
the PID parameter shows:
Take 5 Main O/P control model
use self tuning
control model
use auto tuning
control model
matters needing attention:
When use At control model.
Will have the excess temperature
phenomenon in at calculation process.
Finished until the calculation.
The calculation period PV right
bottom decimal point will glitter.
PV
SV:default=50C
Level 2
Level 3
Manual O/P mode
:enable
Control mode
:disable
See Table 1
Alarm 1 mode
Main O/P
See Table 3
control model
Set Take 5
Alarm 1 dead
band
Range=0~10
Main & Aux. O/P
Heating/cooling
Mode
See Table 2
Alarm 2 mode
See Table 3
Main O/P cycle
time
Range=0~60sec
Alarm 2 dead
band
Range=0~10
Aux. O/P cycle
time
Range=0~60sec
Analog O/P low
limit
Range=0~200
Main O/P propor-
Analog O/P high
Tional band
(Take 6)
Range=0~100C/F
limit
Range=0~200
Main output I time
Soft start output
Range:
time range
(Take 6)
0~250/0.1sec
0~60min
Soft start output
Main O/P different-
Percent range
ial time
(Take 6)
0~100%
Range=0~250/0.1s
Aux. O/P propor-
Level 2
tional band
Range=0~100C/F
Aux. output I time
Range:
0~250/0.1sec
Aux. O/P D time
Range=0~250/0.1s
Main output hyst-
eresis band
(Take 6)
Range:1~100℃/℉
Display in on/off
control mode
Aux. output hyst-
eresis band
Range:1~100℃/℉
Display in on/off
control mode
SV low limit
( ℃/℉ )
Range:Thermocouple
Low limit ~
SV high limit:
( ℃/℉ )
Range:
~
Thermocouple high limit
Cooling delay
Range:
0~30℃/℉
Level 4
Password
Range=0000~9999
Thermocouple
type
See Table 4
℃/℉
Present value
digital filter time
0~60 sec
Unit=
or
℃/℉
Input temp.offset
Range=-99~+99
℃/℉
Main O/P propor-
tional high limit
Range=0~200
Aux. O/P propor-
tional high limit
Range=0~200
Restore default
:usable
:disable
Control mode : Set the control modes of
main and aux. output.
Main output control model:
Set the Auto tuning or Self tuning
Main & aux. output heating & cooling mode:
Set the control modes of main & aux. heat-
ing & cooling
Main output cycle time : Set the cycle time
of main output.
Aux. output cycle time : Set the cycle time
of aux. output.
Main output proportional band : Set the
value P of main output proportional band.
Main output integral time : Set the
value of main output integral time
Main output differential time : Set the value
D of main output differential time.
Aux. output proportional band : Set the
value P of aux. output proportional band.
Aux. output integral time : Set the
value of aux. output integral time
Aux. output differential time : Set the value
D of aux. output differential time.
Main output hysteresis band : Set the
value of main output hysteresis band
Display and adjust in on/off control mode
Aux. output hysteresis band : Set the
value of aux. output hysteresis band
Display and adjust in on/off control mode
SV low limit : Set the SV low limit from
the thermocouple low range to SV high
limit
SV high limit : Set the SV high limit from
SV low limit to the thermocouple high
limit
Cooling delay : Set the range of PV exceed
SV, the system will execute the cooling
Table 1 Output control mode
Main : PID
Aux. : PID
Main : on/off
Aux. : PID
Main : PID
Aux. : on/off
Main : on/off
Aux. : on/off
Table 2 Output heating &cooling control mode
Main :heating Aux. :cooling
Main :cooling Aux. :heating
Table 3 Alarm mode
No alarm
Low limit
High limit
Lo/Hi limit
Low limit standby
Lo/Hi limit standby
Reverse Lo limit
Reverse Hi limit
Reverse Lo/Hi limit
Absolute
Reverse Absolute
Table 4 Input thermocouple type
J0 TYPE
J TYPE without DP,Range: 0~900°C/32 1200°F
~
J1 TYPE
J TYPE with DP, Range: 0.0~900.0°C/32.0~999.9°F
K0 TYPE
K TYPE without DP,Range: 0~1200°C/32~1500°F
K1 TYPE
K TYPE with DP, Range: 0.0~999.9°C/32.0~999.9°F
PT0 TYPE
PT TYPE without DP,Range: -200~500°C/-328~900°F
PT1 TYPE
PT TYPE with DP, Range: -199.9~500.0°C/-199.9~900.0°F
*DP:Decimal point

Parameter description

Level 1
Main output percentage : Display the perc-
entage of main output, and it was controled
by PID control function.
Aux. output percentage : Display the
Percentage of aux. output.
Alarm 1 value : Set the low alarm range of
alarm 1
Alarm 1 value : Set the Hi alarm range of
alarm 1
Alarm 2 value : Set the range of alarm 2
PID auto tuning : Execute the PID value
automatically.
Auto tuning model switch
Level 3
Manual output mode : Switch usable & dis-
able for manual output.
Alarm 1 mode : Set the alarm 1 action mode
Alarm 1 hysteresis band : Set the value of
alarm 1 hysteresis band.
Alarm 2 mode : Set the alarm 2 action mode
Alarm 2 hysteresis band : Set the value of
alarm 2 hysteresis band.
Analog output low limit : Output the low limit
when analog output
Analog output high limit : Output the high
limit when analog output
Soft start output time : Heater dehumidify
Time
Soft start output percent : Heater dehumidify
Output percent
Level 4
Password : Set the password to change the
parameter using and setting.
Thermocouple type : Set the thermocouple
type.
Unit :
or
are selectable
Input temperature offset : Set offset value to
increase or decrease the present tempera-
ture.
Main output percentage high limit : Set the
percentage high limit of main output
Aux. output percentage high limit : Set the
percentage high limit of aux. output
Default value : Restore default from the
user settings.