- ページ 12

照明器具 ECI CabLite ECO 5000KのPDF インストレーション・マニュアルをオンラインで閲覧またはダウンロードできます。ECI CabLite ECO 5000K 14 ページ。

As previously mentioned the CabLite system power supply and dimming board are pre-wired from the
factory. Route AC power through one of the punch outs of the gang box and secure cable to box with
appropriate hardware. Connect AC in as shown in Figure 8 - CabLite ECO with Dimming Wiring.
AC IN line – Brown wire on power supply
AC IN neutral – Blue wire on power supply
Route the 8' cable through another punch out of the gang box and secure to box using proper hardware.
Connect the 8' cable to the first downlight and the remaining downlights with the 4' cables. The two
connectors on the downlights are interchangeable so cable connection does not matter.
Apply power to lighting system and adjust brightness using the potentiometer on the Diming board. (See
Figure 2 - Dimmer Board).
When complete install cover to power unit.
7.5 CabLite ECO w/ Dimming & Emergency Wiring
Figure 9 - CabLite ECO w/ Dimming & Emergency Wiring
As previously mentioned the CabLite system power supply and dimming board are pre-wired from the
factory. The BATTERY negative terminal is prewired to the control board and the positive terminal is
left disconnected. Route AC power through one of the punch outs of the gang box and secure cable to
box with appropriate hardware. Connect AC in as shown in Figure 9 - CabLite ECO w/ Dimming &
Emergency Wiring.
AC IN line – Brown wire on power supply
AC IN neutral – Blue wire on power supply
Route the 8' cable through another punch out of the gang box and secure to box using proper hardware.
Connect the 8' cable to the first downlight and the remaining downlights with the 4' cables. The two
connectors on the downlights are interchangeable so cable connection does not matter.
Cablite ECO Installation Manual Rev 4.0
Electronic Controls, Inc.
7073 North Atlantic Ave. Cape Canaveral, FL 32920
800-633-9788
www.eciamerica.com
P a g e
| 12