- ページ 3

ソフトウェア Epson Perfection 1670 PhotoのPDF 製品情報をオンラインで閲覧またはダウンロードできます。Epson Perfection 1670 Photo 7 ページ。 Color image scanner
Epson Perfection 1670 Photo にも: スタートマニュアル (9 ページ), マニュアル (11 ページ), 更新 (1 ページ), 製品サポート速報 (17 ページ), 製品サポート速報 (12 ページ), 重要な安全上のご注意 (4 ページ), パンフレット&スペック (2 ページ), サービスマニュアル (46 ページ)

Epson Perfection 1670 Photo 製品情報
EPSON Perfection 1670 Photo
Dimensions
Width: 10.8 inches (275 mm)
Depth: 16.5 inches (419 mm)
Height: 3.4 inches (86 mm)
Weight
Approx. 6.8 lb (3.0 kg)
Electrical
Input voltage
AC 100 to 120 V
range
Rated frequency
50 to 60 Hz
Rated input
0.5 A
current
Power
17 W (operating mode),
consumption
15 W (standby mode, 5.5 W sleep mode)
Note: Check the label on the back of the scanner for voltage
information.
Environmental
Temperature
Operation: 41 to 95 °F (5 to 35 °C)
Storage: –13 to 140 °F (–25 to 60 °C)
Humidity
Operation: 10% to 80%
(without
Storage: 10% to 85%
condensation)
Operating
Ordinary office or home conditions; avoid
conditions
extreme dust, direct sunlight, and strong
light sources.
Approvals
Safety
UL 1950
CSA C22.2 950
EMC
FCC part 15 subpart B class B
CSA C108.8 class B
USB Interface
Interface type
Universal Serial Bus Specification
Revision 2.0
Electrical
Full Speed mode: 12 Mbit/s,
Hi-speed mode: 480 Mbit/s,
Universal standard Serial Bus Specification
Revision 2.0
Connector type
One receptacle (Type B)
Option Interface Connector
Output voltage
15.2 V; 50 to 60 Hz
2 - EPSON Perfection 1670 Photo
Initialization Methods
The scanner can be initialized (returned to a fixed set of
conditions) in the following ways:
Hardware
The scanner is plugged in.
initialization
The USB cable is unplugged from the USB port on
the scanner.
Software
Software sends the ESC @ (initialize the scanner)
initialization
command.
The scanner receives a Bus Reset from the USB
interface.

AC Adapter Specifications

Rated input
AC 100 to 120 V, 50 to 60 Hz
Rated output
DC 15.2 V, 1.2 A
Temperature
Operation: 41 to 95 °F (5 to 35 °C)
Safety
UL 1950 or UL60950
CSA C22.2
EMC
FCC part 15 subpart B class B
CSA C108.8 class B

Film Adapter Specifications

Electrical
Supplied voltage: DC 15.2V
Rated current: 0.3 A
Transparencies size 35-mm film strip 3 frames
35-mm slide, 2 frames
Readable area
1.9 4.9 inches (49 125 mm)

Unlocking the Scanner

Be sure to unlock the scanner before using it. Slide the
transportation lock to the unlock position:
If you need to transport the scanner, see page 6.
6/03
Unlocked
Locked