- ページ 11

セキュリティシステム ECKey EK6 seriesのPDF インストールおよび操作マニュアルをオンラインで閲覧またはダウンロードできます。ECKey EK6 series 15 ページ。 Internal/external mounting – red and green led control from access control system
ECKey EK6 series にも: インストーラーズマニュアル (9 ページ)

a.
Refresh – Updates information on this tab.
b.
Get Clock – Retrieves current time from the reader.
c.
Set Clock – Sets reader time to match time from connected PC.
d.
Unlock/Lock – Manually trigger the reader (EK7 only).
e.
Copy to Clipboard – Copies all the information from this tab to PC's clipboard for pasting.
8.

Configuring an EK7 Reader

The following settings are unique to EK7 readers. EK7 readers have several operating modes and the operating mode
will determine the available options.
Setup Tab
a.
Reader Name – Name of connected reader.
b.
Application – Defines the type of application the reader is being configured for. Options for the EK7 are:
i.
Door Lock
ii.
Gate/Garage Opener
c.
Relay Type – Defines how the relay operates when the EK7 is triggered (dependent on Application selected
above). Options are:
i.
Unlock simulated button press – Relay is activated for Open Pulse Length then deactivates and
resumes searching for phones. Set the Minimum Delay period to the time the door will be held
open from this activation. Reader will resume searching for phones after Min. Delay period has
passed.
ii.
Unlock when phone is in range – Relay will be activated while phone is in range (or the Minimum
Delay period, whichever is longer), and then deactivates when phone moves out of range. If multiple
phones overlap, the relay will remain activated until all phones have left range.
iii.
Unlock for a period – Relay is activated for Open Pulse Length then deactivates. Reader resumes
searching for phones after Minimum Delay period has passed since previous trigger.
ECKey Installation and Operation Guide
11