- ページ 8
ドア開閉システム CROWN INDUSTRIAL Aut-o-doR 1266のPDF クイック・スタート・マニュアルをオンラインで閲覧またはダウンロードできます。CROWN INDUSTRIAL Aut-o-doR 1266 12 ページ。 Slide door operators
REVERSING STARTER TERMINALS
2
3
o
4
o
5
o
6
o
7
o
o
X2
©
NOTE:
On 115 volt power source
terminal # 1 is L 1 and
terminal #X2 is L2.
LSL
I
O~E~~
....
O:::=T~-
....
--f----+--+--O
I
N.C.
LIMIT SWITCH
L __
----.J
PUSHBunON
STATION
SITE WIRING
X2
Xl
2
L
R
5
....._ _
O()C<~~
_ _
J
Wiring is shown for door movement to the left to open. If door opens to the right, wire the
open button to reversing starter terminal #5 and the close button to reversing starter
terminal #3.
CONTROL WIRING
WIRING DIAGRAMS FOR "OPEN"-"CLOSE"-"STOP" PUSHBUnON
CONTROL OF OPERATOR
R-W CLASS "B" WIRING CIRCUIT
WIRING
CODE
Heavy Lines Site Wiring
Lighter Lines - Factory Wiring
Additional control stations may be applied to this control circuit by wiring the "Stop" contacts of all stations in series with the
"Stop" pushbutton shown. Wire "Open" and "Close" contacts in parallel with "Open" and "Close" pushbutton shown. Note that
all "Stop contacts" must be wired in series in the wire from terminal number 1 prior to supplying "Open" or "Close"
contacts.
.
RICHARDS-WILCOX MFG. CO. AURORA, ILLINOIS
Page 8