EPSON Stylus Pro 10600
Electrical
Specification
120V Model
Input voltage range
90 to 132V
Rated frequency range
50 to 60 Hz
Input frequency range
49 to 61 Hz
Rated current
1.4 A
Power consumption
Approx. 131 W (ISO 10561 Letter Pattern)
30 W or less in sleep mode
Mechanical
Dimensions
Width: 73.4 inches (1865 mm)
Depth: 28.0 inches (710 mm)
Height: 48.2 inches (1225 mm)
Weight
284 lb (129 kg) with stand
Paper
The allowable paper dimensions are shown below:
Roll paper
Size
8.3 to 44 in. wide
(210 to 1118 mm)
Maximum
2 in. core: 4 in. (103 mm)
external roll
3 in. core: 6 in. (150 mm)
diameter
Thickness
3.15 to 19.7 mil (0.8 to
0.5 mm)
Notes:
❏
Poor quality paper may reduce print quality and cause paper jams
and other problems. If you encounter problems, switch to a
higher grade of paper.
❏
Do not use curled, folded, or deckle-edge paper.
❏
Depending on the media, best feed and print quality are
guaranteed on EPSON paper with thicknesses of 3.15 to 4.33 mil
(0.08 to 0.11 mm), 64 to 90 gsm.
❏
For best results, use paper under the following conditions:
Temperature:
59 to 77 °F (15 to 25 °C)
Humidity:
40 to 60% RH
2 - EPSON Stylus Pro 10600
220−240V Model
198 to 264V
0.7 A
Cut sheets
8.5 × 11 in. up to 44 in.
wide
—
3.15 to 59 mil (0.8 to
1.5 mm)
9/02
Environmental
Temperature
Operation: 50 to 95 °F (10 to 35 °C)
Storage:
Transit
Humidity
Operation: 20 to 80% RH
(without
Storage:
condensation)
Transit
Safety Approvals
Safety standards UL 1950, CSA C22.2 No. 950 FDA
EMC
FCC part 15 subpart B, class A,
CSA C108.8 class A
Ink Cartridges
Cartridge life:
Photographic Dye ink
2 years from production date
UltraChrome and Archival ink
2 years from production date if unopened;
within 6 months after opening package, at
77 °F (25 °C)
Temperature:
Storage (uninstalled):
22 to 104 °F (
–
°F (40 °C)
Storage (installed):
4 to 104 °F (
–
°F (40 °C)
Transit
:
22 to 140 °F (
–
°F (40 °C), 120 hours at 140 °F (60 °C)
Freezing:
14 °F (
10 °C); ink thaws and is usable after
–
at least 3 hours at 77 °F (25 °C)
Capacity
500 ml
4 to 104 °F (
20 to 40 °C)
–
–
1 month at 104 °F (40 °C)
4 to 140 °F (
20 to 60 °C),
–
–
stored in shipping container
120 hours at 140 °F (60 °C)
20 to 85% RH
5 to 85% RH (stored in
shipping container)
30 to 40 °C); 1 month at 104
–
20 to 40 °C); 1 month at 104
–
30 to 60 °C); 1 month at 104
–