Eliminated portion.................... Leading edges: 3.0±2.0 mm, Side/trailing edges: 2.0±2.0 mm (copy)
Paper feeding .......................... Standard drawers:
Capacity of originals in the reversing automatic document feeder (Option)
.................................................. A3 to A5-R, LD to ST-R:
Automatic duplexing unit (ADU is available as standard equipment for some destinations or versions.)
.................................................. Stackless, Switchback type
Toner supply ............................ Automatic toner density detection/supply
Density control......................... Automatic density mode and manual density mode selectable in 11
Weight ..................................... Approximately 75 kg (165.34 lb.): e-STUDIO200L/230/230L/280/280S
Power requirements ................ AC 110 V / 13.2 A, 115 V or 127 V / 12 A
* The acceptable value of each voltage is ±10%.
Power consumption................. 1.5 kW or less (115 V series, 200 V series)
* The electric power is supplied to the RADF, (ADU), Finisher, Job Separator, Offset Tray, PFP and
LCF through the equipment.
Total counter............................ Electronical counter
e-STUDIO200L/202L/230/232/280/282 SPECIFICATIONS / ACCESSORIES / OPTIONS / SUPPLIES
Leading / trailing edges: 5.0±2.0 mm, Side edges: 5.0±2.0 mm (print)
1 or 2 drawers (stack height 60.5 mm, equivalent to 550 sheets;
2
64 to 80 g/m
(17 to 22 lb. Bond)): Depends on destinations or
versions.
PFP:
Option (One drawer or two: stack height 60.5 mm, equivalent to
550 sheets; 64 to 80 g/m
LCF:
Option (Stack height 137.5 mm x 2: equivalent to 2500 sheets;
2
64 to 80 g/m
(17 to 22 lb. Bond))
Bypass feeding:
Stack height 11 mm: equivalent to 100 sheets; 64 to 80 g/m
to 22 lb. Bond)
100 sheets / 80 g/m
Toner cartridge replacing method (There is a recovered toner supply
mechanism.)
steps
Approximately 77 kg (169.75 lb.): e-STUDIO202/232/232S/282/282S
(include the developer material and drum) (The ADU and Drawer mod-
ule are installed.)
220-240 V or 240 V / 8 A (50/60 Hz)
1 - 4
05/11
2
(17 to 22 lb. Bond))
2
(Stack height 16 mm or less)
June 2004 © TOSHIBA TEC
2