Trouble indications

The indicator lights inform you of interminal abnormalities.
POWER
POWER
(Red lit)
(Red lit)
POWER
POWER
FLASH
POWER
FLASH
FLASH
No power
⇒ Problem with projector
• Unplug the power cord, and contact your dealer.
Lamp went out during use, or won't come on
⇒ Lamp temperature is high so that it is difficult to turn on, the lifetime of
the lamp has ended or the projector is malfunctioning.
• Unplug the power cord and wait for a short while, then turn the power
back on.
• If a lamp burns out, replace it with a new one.
❈ After approx. 5 second of abnormal display, the projector returns to
the standby state waiting for internal cool down.
Power went out during use
⇒ Internal overheating, or the outside temperature is too high.
• Place the projector so that the air intake and exhaust are not
blocked.
• Unplug the power cord and wait for a short while, then turn the power
back on.
❈ The
icon will appear before the power goes out.
❈ After approx. 5 second of abnormal display, the projector returns to
the standby state waiting for internal cool down.
Power went out during use
⇒ Problem with internal cooling fan.
• Unplug the power cord, and contact your dealer.
❈ The
icon will appear before the power goes out.
❈ After approx. 5 second of abnormal display, the projector returns to
the standby state waiting for internal cool down.
Power went out during use
⇒ Problem inside the projector.
• Unplug the power cord and wait for a short while, then turn the power
back on.
• If the above action will not clear the problem, unplug the power cord,
and contact your dealer.
❈ The
icon will appear before the power goes out.
❈ After approx. 5 second of abnormal display, the projector returns to
the standby state waiting for internal cool down.
41