- ページ 6

ネットワーク・ハードウェア CRU RTX 800-TRのPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。CRU RTX 800-TR 11 ページ。 Enclosure
CRU RTX 800-TR にも: クイック・スタート・マニュアル (2 ページ)

5.2 Enable Auto-Rebuild

When Auto-Rebuild is enabled, the RTX enclosure will
automatically use any suitable unallocated drive it finds
as a replacement for a faulted drive. Suitable drives must
be large enough to replace the degraded drive and cannot
contain any RAID group information. If a Hot Spare Pool
exists, the RTX enclosure will default to using an available
Hot Spare drive from the pool before searching for an
unallocated drive.
Refer to Section 6 for instructions on how to enable Auto-
Rebuild.

6 Change RAID Group Properties

Some of these properties can
only be specified during the
creation of the RAID group while
others may be changed at any
time during the life of the RAID
group.
a. Use the ATTO ConfigTool
to
log
in
to
ThunderStream
3808E properties as detailed
in Section 3.2.3 , Steps A
through E.
b. Right click on the RAID Group in the Groups panel
listing and click on Properties.
c. Modify the current properties according to your needs:
SpeedRead
Specifies the cache policy used during read operations.
Setting
Never
Read caching is disabled
Always
Read caching is always enabled
Adaptive
Read caching is adaptively enabled so read performance
(default)
remains high
Page 6
the
SC
Description
Auto-Rebuild
Controls the replacement of a faulted drive with any
available unallocated drive. When you click on the
Auto-Rebuild check box and the Accept button, Auto-
Rebuild is enabled. If a drive becomes faulted, the SAS/
SATA RAID storage controller replaces the drive with an
unallocated drive.
Rebuild Priority
Specifies the ratio of rebuild I/O activity to host I/O
activity.
Setting
Same
Both rebuild and host I/O's are treated equally
(default)
Low
Host I/O is given higher priority
High
Rebuild I/O is given higher priority
Prefetch
Specifies the number of stripes that are read when
SpeedRead is enabled or adaptive. This property can
only be changed after the RAID group is created. To
access this property, select the RAID group and view its
properties.
d. Click Accept.
7 Recovering From a Failed Hard Drive or
RAID Group
Use the chart below to diagnose the issue you are experiencing
and the recovery method you should use to restore the RAID
or recover your data.
Failure Scenario Table
RAID
Reason(s) for Being
Level
Marked Offline
JBOD/
Any drive failure
RAID 1
Error on one drive
RAID 1/
Mistaken replacement of
RAID 10
good drive when its mirror
has failed
Error during rebuild
Error on one drive
Mistaken replacement of a
good drive when another
RAID 4/
member of its RAID group
RAID 5
has failed
Error during rebuild
Errors on two or more
drives
Description
Recovery Method
Section 7.2: Data Recovery
Section 7.1.1: Automatic Replace-
ment or Section 7.1.2: Manual Re-
placement
Section 7.1.3: Recovery from Re-
placement of a Wrong Drive
Section 7.2: Data Recovery
Section 7.1.1: Automatic Replace-
ment or Section 7.1.2: Manual Re-
placement
Section 7.1.3: Recovering from
Replacement of a Wrong Drive
Section 7.2: Data Recovery
Section 7.2: Data Recovery
CRU Mark
10.25.12
PMS 711
2 cyan