Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user
needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow to configure signed values. In order to set values in the range 128 ... 255 the value sent in the
application shall be the desired value minus 256. For example: to set a parameter to 200  it may be needed to set a value of 200 minus 256
= minus 56. In case of two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Enable/Disable waking up (Parameter Number 2, Parameter Size
mode) the MultiSensor.
Value
0
1
default PIR time (Parameter Number 3, Parameter Size
(0x00) to the associated nodes if no motion is triggered again in 4 minutes.
Value
Description
10 —
The time unit is second if the value range is in 10 to 255. Default Value is 240.
255
256 —
If the value range is in 256 to 3600, the time unit will be minute and its value should follow the below rules: a), Interval time =Value/60, if the interval time
3600
can be divided by 60 and without remainder. b), Interval time= (Value/60) +1, if the interval time can be divided by 60 and has remainder. Other values will
be ignored.
Enable/disable the function of motion sensor. (Parameter Number 4, Parameter Size 1)
Value
Description
0
disable (Default)
1
enable, the current PIR sensitivity level=1. (minimum level)
1)Enable/Disable waking up for 10 minutes when re-power on (battery
Description
disable (Default)
enable
2)The default PIR time is 4 minutes. The Multisensor will send BASIC SET CC