- ページ 2

リモコン Aeon Labs KeyFobのPDF マニュアルをオンラインで閲覧またはダウンロードできます。Aeon Labs KeyFob 5 ページ。 Z-wave

2.
Bring your primary Z-Wave controller in the inclusion mode.
3.
Press the Learn button on the backside of the Key Fob.
4.
If succesful, the green and red LED on the front of the Key Fob will alternatively blink followed by the green LED illuminating for
2 seconds.
5.
If not succesful, the red LED will illuminate for 2 seconds.
To exclude the Key Fob from the Z-Wave network repeat the steps above.

Operating the device

The Aeon Labs Key Fob can operate in three different modes: SETUP, GROUP and SCENE Mode.
When the device is first time powered up it is in Setup Mode. This allows you to setup the Key Fob and do everything from creating
a new Z-Wave network through to removing devices from one. In this mode the buttons operates as shown in the picture.
To change your Key Fob to Group Mode open the main panel of the device so that you can see the internal light. Use the provided
Button pin to press the Mode button. The LED will illuminate for a second to confirm that the mode has been changed successfully
to Group Mode.
If you wish to change your Key Fob to Scene Mode, you'll need to configure it with your Z-Wave gateway. Please refer to the
gateway's manual for this.
Setup Mode
For an existing Z-Wave network
Your Key Fob works perfectly as an additional remote control within an existing Z-Wave network.
For a new Z-Wave network
Your Key Fob can be set as the primary controller of a Z-Wave network. This is recommended where you don't already have a Z-
Wave network set up and you're either starting out or intending to set up only a small system. As a primary controller of a new Z-
Wave network, your Key Fob will be able to operate in Setup and Group Mode.
In this case you need to associate your Z-Wave devices with the Key Fob. For details refer to the "Inclusion" part of this manual.
2