- ページ 8

計測機器 Aeon Labs AEO HEM2-100AのPDF クイック・スタート・マニュアルをオンラインで閲覧またはダウンロードできます。Aeon Labs AEO HEM2-100A 11 ページ。 Z-wave clamp power meter 2nd generation - two clamps max. 100 ampere

Report Type send in Reporting Group 3 (Parameter Number 103, Parameter Size 4) Defines the type of
report sent for the Reporting Group 3.
Value
Description
1
Battery Report
2
MultiSensor Report for the whole device
4
Meter Report for Watt for the whole device
8
Meter Report for kWh for the whole device
256
Meter Report for Watt for clamp 1
512
Meter Report for Watt for clamp 2
1024
Meter Report for Watt for clamp 3
2048
Meter Report for kWh for clamp 1
4096
Meter Report for Watt for clamp 2
8192
Meter Report for kWh for clamp 3
Set 111-113 to default (Parameter Number 110, Parameter Size 1)
Value Description
Send Interval for Reporting Group 1 (Parameter Number 111, Parameter Size 1) Defines the time interval
when the defined report of Reporting Group 1 is sent out.
Value
Description
0 — 255 Seconds (Default 1)
Send Interval for Reporting Group 2 (Parameter Number 112, Parameter Size 1) Defines the time interval
when the defined report of Reporting Group 2 is sent out.
Value
Description
0 — 255 Seconds (Default 1)
Send Interval for Reporting Group 3 (Parameter Number 113, Parameter Size 1) Defines the time interval
when the defined report of Reporting Group 3 is sent out.
(c) 2012 Z-Wave Europe GmbH, Goldbachstr. 13, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 8