A-07
|
5. ADJUSTMENTS
. Connect the measurement equipment.
. Set VR105 (VR106) for DC balance adjustment to the center position.
. Turn VR101 (VR102) for idle current adjustment counterclockwise as far as it will go.
. Turn the VOLUME control on the front panel counterclockwise as far as it will go.
. Turn on the power.
. Adjust VR101 (VR102) so that @ (Q) is +22 mV+5 mV with respect to ® (®).
. Adjust VR105 (VR106) so that © (®) is 0 mV +3 mV with respect to the negative terminal of a Lch (Rch) speaker.
SI
ADUn
PWN
Note: Adjust five minutes or more after the power is turned on.
MOTHER
ASSY
Connection and Adjustment Point
24