- ページ 8
モニター Pioneer PDK-5011のPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Pioneer PDK-5011 17 ページ。 Hung on wall unit
7
Fix the bottom of the hardware with the special
screws removed at step 1 (one on the left and one
on the right).
Special screw (M6)
A Criterion for the vertical
location
Gap
disappears
Wall side hardware
When it is in this state, do not turn
the adjustment screw any further in
the closing direction.
Closing
A
Resin plate
8
En
B Criterion when its angle
Back of the
plasma display
Resin plate
When it is in this state, do not turn the
adjustment screw any further in the
opening direction.
Opening
Hexagon wrench
B
7 Angle setup
This installation hardware allows the display to be directed
downwards freely at any angle from the vertical to 25°.
This adjustment must always be done by 2 people.
Adjust the angle by rotating the screws at the center top and
center bottom of the wall side hardware to the left or right.
Warning
• If the angle is increased while you are adjusting the angle
using the screw at the center of the bottom, it is difficult to
turn the screw. When this happens, adjust it at the center
of the upper.
• Turn the screws very carefully to avoid damaging the wall.
• When a screw becomes tight at either end of the adjust-
ment range, do not turn the adjustment screw any further,
because if you do, you will apply excessive force, deform-
ing the screw.
is 25°
End face of the plate
Matched in both
directions
Notch
Measuring the opening distance X enables approximate
angle values to be determined.
X
133 mm
188 mm
241 mm
291 mm
X
Angle
5°
10°
15°
20°