- ページ 10
モニター Pioneer PDP 502MXのPDF マニュアルをオンラインで閲覧またはダウンロードできます。Pioneer PDP 502MX 11 ページ。 Rs-232c control for plasma display monitor, serial commands and protocol
Pioneer PDP 502MX にも: パンフレット&スペック (8 ページ), ニュースレター (1 ページ), ニュースレター (1 ページ), 取扱説明書 (44 ページ)
Combination Connection
If the following connection conditions are observed, extension of operations to as many as 16 units is guaranteed.
Conditions:
1 Length of RS-232C cable connecting PC to PDP-502MX: 5 m
2 Combination cable length: 5 m for each
3 Wire specifications for linking cable: Mini Din 6-pin straight (7 strand cable)
(NOTE) Refer to section 2.3, "Controls and Connectors" regarding the number of units that can be connected when
series connection is made while using a video output terminal (INPUT 1 or 4).
122
PC
RS-232C
Combination cable 5m
For 1 strand, suitable for AWG28:
Cross-section area = 0.08 mm
≠
7 strands × π r
= 7 × 3.14 × 0.06
2
PDP-502MX
1
OUT
IN
2
OUT
IN
3
OUT
IN
#
2
2
= 0.079 mm
2
0.08 mm
2