- ページ 32

ウォーターヒーター Ariston 65 DRYのPDF マニュアルをオンラインで閲覧またはダウンロードできます。Ariston 65 DRY 41 ページ。

ADJUSTING THE TEMPERATURE AND ACTIVATING THE FUNCTIONS (Fig. 8)
Switch the appliance on by pressing the ON/OFF " button. Set the desired temperature by selecting a level
+
-
between 40°C and 80°C using the "
" and "
" buttons. During the heating phase, the LEDs relateci to the
temperature (40°C --> 80°C) reached by the water remain on; the subsequent ones, until the temperature is
set, flash progressively. lf the temperature drops, tor example due to water being drawn, the heating is auto
matically reactivated and the LEDs between the last one on (steady) and that relateci to the set temperature
start to flash progressively again.
In the event of a power failure, or if the product is turned off using the ON/OFF " button, the last temperature
set remains memorized. During the heating phase, a slight noise may occur due to the heating of the water.

ANTI-FREEZE FUNCTION

The anti-freeze function is the appliances automatic protection to avoid damages caused by very low tempe
ratures below 5 °C, in the event in which the product is turned off during winter. It is recommended that the
product remains plugged in to the mains power, even if iiis inactive for a long time.
Attention: the function is enabled, but it is not indicated in case of activation. Once the temperature rises to a
safer level such as to avoid damage from ice and frost, the water heating is switched off again.
ECO EVO FUNCTION
The "ECO" function is a software program that automatically "learns" user consumption levels, redu cing heat
loss to a minimum and maximising energy savings. The "ECO" software consists of an initial saving period of
a week, when the product begins to operate at the temperature set. Al the end of this "le arning" week, the
software adjusts water heating according to the user's real needs which are automatically identified by the
appliance. The product guarantees a minimum reserve of hot water even during periods in which water is not
withdrawn. The hot water demand learning process, continues even after the first week. The process achieves
maximum efficiency after four weeks of learning. Activate the function by pressing the ECO " "button, which
will light up. In this mode, the manual selection of the temperature is possible, however changing iidisables the
"ECO" function. Reactivate it by pressing the ECO " " button, which will light.
Whenever the "ECO" function or the product is turned off and on again, the function will continue to le arn
the levels of consumption. In order to guarantee proper operation of the program, it is recommended not to
disconnect the appliance from the mains. An internal memory ensures data storage for up to 4 hours wi thout
electricity, after which all acquired data is cancelled and the learning process will begin from the start.
Each time to set the temperature, the "ECO" function is automatically disabled and the relative writing turns off.
The product continues to operate with the program selected, the ECO function is not active.
To voluntarily cancel the acquired data, hold down the ECO " " button for more than 5 seconds.
When the reset process is completed, "ECO" flashes quickly to confirm data cancellation
THERMAL DISINFECTION FUNCTION (ANTI-LEGIONELLA)
The anti-Legionella function is activated by default. It consists of a water heating/60°C temperature mainte
nance cycle for 1 hour which has a thermal disinfection action on the relative bacteria.
The cycle starts when the product is started up and when it is restarted after a power outage. If the product
always functions at temperatures lower than 55°C, the cycle is repeated after 30 days. When the product
is switched off, the anti-Legionella function is deactivated. If the equipment is switched off during the anti
Legionella cycle, the product switches off and the function is deactivated. At the end of the cycle, the use
temperature returns to the temperature previously set by the user.
The activatio of the anti-legionella cycle appears as a normai temperature adjustment 60°C.
+
Activate this function by pressing and holding both the ECO " " and "
" buttons tor 4 s.; once activation is
confirmed, LED 60°C will flash quickly tor 4 s. Permanently deactivate the function by repeating the above
steps; once the deactivation is confirmed, LED 40°C will flash quickly tor 4 s."
32 / EN