- ページ 12

ウォーターヒーター Ariston HS PREMIUMのPDF テクニカル・インストラクションをオンラインで閲覧またはダウンロードできます。Ariston HS PREMIUM 32 ページ。 Condensing wall thermal power plant

Ariston HS PREMIUM テクニカル・インストラクション
Machine Translated by Google
INSTALLATION
Connection of Suction and Exhaust Pipes
burned
The boiler is suitable for operation in mode B taking air from the
environment and in mode C taking air from outside.
When installing an exhaust system, pay attention to the insulation to
avoid the infiltration of flue gases into the air circuit.
The exhaust kit must not be tilted
position because the coaxial tube is already tilted to the boiler.
In the case of a type B installation, the room in which the boiler is installed
must be ventilated by an adequate air intake and in accordance with the
regulations in force. In rooms with a risk of corrosive vapors (for example:
laundries, hairdressing salons, galvanic process media, etc.) it is very
important to use a type C installation with external air supply (combustion)
for combustion. This protects the plant from the effects of corrosion.
For the realization of a coaxial type aspiration / evacuation system it is
mandatory to use the original accessories.
Flue gas pipes must not come into contact with flammable materials, nor
must they be installed near them, nor must they pass through structures
or walls made of flammable materials.
The connection (connection) of the flue gas pipes is made with a male /
female connection (plug) and a sealing gasket.
The connections must be placed against the direction of condensate
leakage.
Typology of connecting the boiler to the chimney
- coaxial connection of the boiler to the chimney /
evacuation,
- double connection of the boiler to the exhaust chimney with the suction
of outside air,
- double connection of the boiler to the exhaust chimney with the suction
of ambient air.
Condensation-resistant products must be used when connecting the
boiler to the chimney. For connection lengths and changes, see the
exhaust type table.
Suction connection kits (flue gas are supplied separately from the
appliance depending on the various installation solutions. The boiler is
designed for connection to a coaxial flue gas suction and exhaust system.
The connection of the boiler to the chimney is carried out on all appliances
with coaxial tubes Ø 60/100.
For pipe leakage, see flue gas catalog. The additional resistance must
be taken into account in the above dimension.
For the calculation method, equivalent length values and installation
examples, see the flue gas catalog.
CAREFUL
MAKE SURE THE EXHAUST
AND VENTILATION PIPES ARE NOT
OBSTRUCTED.
CAREFUL
MAKE SURE THERE ARE NO GAS LEAKS IN
THE EXHAUST PIPES.
ONLY BURNED GAS EXHAUST KITS WILL BE USED
FOR CONDENSING POWER PLANTS
12 /
but mounted in a horizontal
,
The boiler is arranged to be connected to a 60/100 coaxial flue gas
suction and exhaust system.
To use the mounting type with two separate ducts (one suction and one
exhaust), it is necessary to use one of the two air intakes.