Dimension / Functions and Usage
5. Dimension
96.5
6. Functions and Usage
6.1 Speed Adjustment Method
This drive provide below two adjust methods for the user to choose:
Inner potentiometer speed adjustment : rotate the potentiometer on the driver panel
counterclockwise, the rotate speed of the motor will decrease, rotate the potentiometer on
the driver panel clockwise, The rotate speed become higher. If you use external input to
adjust speed, make sure the potentiometer is set in the min. state.
External speed adjustment : Connect on the GND and +5V of the drives, speed can be
adjusted on external potentiometer ((5K~100K) when connect SV terminal. Input simulate
voltage through other control command (e.x. PLC, SCM etc.) to SV terminal to achieve the
speed adjust as well (relative GND). The range of the SV terminal is DC OV~+5V, the
relevant motor speed is 0~rated speed.
External digital signal speed regulation : Add 5V between SV and GND, speed can be
adjusted by PWM control between the 1KHz~2KHz, motor speed is influenced by duty. At
this time, by adjusting the R-SV potentiometer, SV digital signal amplitude can be 0~1.0 ratio
: 150×97×48mm
48
P/A
R-SV
5
page│5