- ページ 8
スイッチ Aeotec AEOEZW116のPDF クイック・スタート・マニュアルをオンラインで閲覧またはダウンロードできます。Aeotec AEOEZW116 11 ページ。 Single nano switch with measuring
Aeotec AEOEZW116 にも: マニュアル (16 ページ)
Parameter 100: Set parameter 101-103 to default value.
Set parameter 101-103 to default value.
Size: 1 Byte, Default Value: 0
Setting
0
Parameter 101: To set which reports need to be sent in Report group 1.
To set which reports need to be sent in Report group 1.
Size: 4 Byte, Default Value: 0
Setting
1
2
4
8
Parameter 102: To set which reports need to be sent in Report group 2.
To set which reports need to be sent in Report group 2.
Size: 1 Byte, Default Value: 0
Setting
1
2
4
8
Parameter 103: To set which reports need to be sent in Report group 3.
To set which reports need to be sent in Report group 3.
Size: 1 Byte, Default Value: 0
Setting
1
2
4
8
Parameter 110: Set parameter 111-113 to default value.
Set parameter 111-113 to default value.
Size: 1 Byte, Default Value: 0
Setting
0
Parameter 111: Set the interval of automatic report for Report group 1.
Set the interval of automatic report for Report group 1.
Size: 4 Byte, Default Value: 3
Setting
1 - 2147483647
Parameter 112: Set the interval of automatic report for Report group 2.
Set the interval of automatic report for Report group 2.
Size: 4 Byte, Default Value: 600
Setting
1 - 2147483647
Parameter 113: Set the interval of automatic report for Report group 2.
Set the interval of automatic report for Report group 3.
Size: 4 Byte, Default Value: 600
Description
Reset the parameter 101-103
Description
Send Meter Report of voltage (V)
Send Meter Report of current (A)
Send Meter Report of wattage (W)
Send Meter Report of energy (kWh)
Description
Send Meter Report of voltage (V)
Send Meter Report of current (A)
Send Meter Report of wattage (W)
Send Meter Report of energy (kWh)
Description
Send Meter Report of voltage (V)
Send Meter Report of current (A)
Send Meter Report of wattage (W)
Send Meter Report of energy (kWh)
Description
Reset the parameter 111-113
Description
The range of interval time is 1 to 2147483647.
Description
The range of interval time is 1 to 2147483647.