- ページ 9

ウォーターヒーター Ariston TOP WIFIのPDF マニュアルをオンラインで閲覧またはダウンロードできます。Ariston TOP WIFI 36 ページ。

Ariston TOP WIFI マニュアル
ERROR
This is a safety error.
If heating is running and heating resistances are switched off,
T_FnctRelaySwitchedOff = T_ vg and then the control board shall switched to
the FUNCTION_CHECK state (functional relays off, safety relays on): here the
program shall check if in T_WINDOW_S FETY (240) minutes T_ vg remains
smaller than T_FnctRelaySwitchedOff + StuckRelayTh (13 °C). If this condition
Error
is not satisfied for at least 15 s, the error condition REL Y_STUCK shall occur
Relay Stuck
elsewhere if the T_WINDOW_S FETY elapses without detecting the error, this
condition shall not be checked anymore (all relays shall be switched off).
Error
Dry Heating
This is a safety error.
If NTC1 probe is well working (no NTC1 shorted or open error condition
detected), the overheating error test can be carried out: if T_NTC_High > 105
°C for at least 3 s, the NTC1 overheating error shall be set. Similarly, if NTC2 is
NTC
working and temperature is > 105 °C for at least 3 s, the NTC2 overheating
High/Low
error shall occur.
This is a not volatile error: the machine shall be locked until the error is
Overheating
removed with a reset condition.
Error Bad
Data Flash
Error
Cant Unlock
8
PHENOMENON