IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be t
value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same
applies: Values greater than 32768 may needed to be given as negative values too.
Parameter 32: Level of low battery
Define a battery level as the low battery.
Size: 1 Byte, Default Value: 20
Setting
10 - 50
Parameter 41: Enable send central scene notification.
Set of sending central scene notification or not.
Size: 1 Byte, Default Value: 1
Setting
0
1
Parameter 42: Setting the duration value of the command switch multilevel.
Setting the duration value of the command switch multilevel.
Size: 1 Byte, Default Value: 255
Setting
0 - 255
Parameter 43: Enable/disable the buzzer alarm when battery is running low.
Set the buzzer alarm or not when battery is low.
Size: 1 Byte, Default Value: 0
Setting
0
1

Technical Data

Dimensions
Weight
Hardware Platform
EAN
IP Class
Voltage
Battery Type
Device Type
Network Operation
Z-Wave Version
Certification ID
Z-Wave Product Id
Frequency
Maximum transmission power
http://manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZWA003
Description
when the value is 10% to 50%,it will send a low battery command.
Description
Disable
Enable
Description
The higher the value,the long the duration value of the command switch multilevel
Description
Disable
Enable
50 x 50 x 14 mm
26 gr
ZM5101
1220000016118
IP 20
3,6 V
1 * LIR2450
Wall Controller
Portable Slave
6.71.01
ZC10-18036056
0x0371.0x0002.0x0003
Europe - 868,4 Mhz
5 mW
30-09-2020 13:08