- ページ 14
ボイラー Ariston EuroCombi Type C A27 MFFIのPDF 取付説明書をオンラインで閲覧またはダウンロードできます。Ariston EuroCombi Type C A27 MFFI 28 ページ。 Type c boiler
Ariston EuroCombi Type C A27 MFFI にも: 取付説明書 (24 ページ), 整備要領 (32 ページ), 整備要領 (32 ページ), 整備要領 (32 ページ)
2.10 Room Thermostat
Connection
5
D
14
In order to perform this procedure, remove boiler cover as indicated in section
3.2. Then proceed as follows:
1 Remove the screws "A" located on the bottom part of the boiler;
2 Widen the sides so that the control panel can be rotated.
3 Open the cover "B" on the left hand side of the compartment.
4 Insert the wire for the connection of the room thermostat into the wire
holder "C", as indicated in photo 3.
1
A
3
5 Remove the grommet "D" shown in photo 5, make a hole in it and pass
the room thermostat wire through.
6 Remove the link located on the terminal and connect the wire.
7 Replace the grommet and the terminal to their original positions, close the
cover on the grommet compartment and fasten the wire-clamp "C" in place.
8 If a remote time clock is to be fitted, disconnect the integral time clock plug
from the P.C.B.
9 Using a volt-free switching time clock, connect the switching wires from the
time clock following points 1-7 above.
10 If using a time clock and room thermostat, these must be connected in
series as per points 1-9 above.
Note: Only a two-wire type room thermostat can be used.
6
2
4
C
B
7
C
B023