- ページ 11
ボイラー Ariston GENUS 30のPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Ariston GENUS 30 20 ページ。
SHUTDOWN PROCEDURE
(FOR ALL MODELS)
To turn off the main burner, simply press the On/Off
switch "L"; the green L.E.D. "I" will also turn off.
As a precautionary measure, it is recommended that
the gas cock located on the bottom of the boiler be
turned off as well.
TIME CLOCK
The steps marked with the symbol ‹ are necessary to carry out a
switching program.
‹ PREPARING FOR OPERATION
Activate the "Reset" switch to reset the time switch to it's default settings
(activate using a pencil or similar pointed instrument). Do this:
- every time you wish to "Reset" the time switch;
- to erase all switching times and the current time of day
B003
After approximately two seconds the following display appears:
I
L
‹ ENTER CURRENT TIME AND WEEKDAY
Weekdays blinks
Input time
Enter
switching time
Summer and
winter time
Reset
setting
Keep the "
" key pressed down. During the summer
time period press the +/-1h key once.
Enter the hour using the "h" key.
Enter the minutes using the "m" key.
Enter the day using the "Day" key.
1 = Mon ....... 7 = Sun
Release the "
" key.
Enter minutes
Enter the hour
Manual switch
Enter weekdays
11