- ページ 17

ボイラー Ariston GENUS 41-116-01のPDF サービスマニュアルをオンラインで閲覧またはダウンロードできます。Ariston GENUS 41-116-01 44 ページ。 Type c
Ariston GENUS 41-116-01 にも: 取付説明書 (32 ページ)

Ariston GENUS 41-116-01 サービスマニュアル
A3
A4
B005
Supplied By www.heating spares.co Tel. 0161 620 6677

Removing the expansion vessel

1. Remove nut "A3" away from the expansion vessel
(see fig. 1.44) ;
2. Remove nut "A4" (see fig. 1.45) ;
3. Remove expansion vessel (see fig. 1.46) .
Fig. 1.44
Fig. 1.45

Removing the overheat thermostat

1. Remove the electrical connector by the overheat
2. Pull off the thermostat connections. Then remove the
Fig. 1.47

Removing the heating temperature sensor (N.T.C.)

1. Remove the electrical connector by pulling off the
thermostat connections and unscrewing the sensor
probe with a 14 mm open ended spanner (see fig.
1.48) .
Fig. 1.48
thermostat (see fig. 1.47 );
thermostat from the pipe by releasing it's securing clip.
Fig. 1.46
17