- ページ 11

ボイラー Ariston GENUS HE 30のPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Ariston GENUS HE 30 16 ページ。 Condensing wall hung system boiler
Ariston GENUS HE 30 にも: ユーザーマニュアル (16 ページ)

Ariston GENUS HE 30 ユーザーマニュアル
MENU 4 - MENU 5
PARAMETERS HEATING ZONA 1 & 2
description
"Display text"
4
ZONE1 PARAMETERS
4
0
SETPOINTS
4
0
0
Setting day
temperature
Zone 1
"Zone1 T Day"
4
0
1
Setting night
temperature
Zone 1
"Zone1 T Night"
4
0
2
Setting fixed tem-
perature Central
Heating
"FIX Temp."
5
ZONE2 PARAMETERS
5
0
SETPOINTS
5
0
0
Setting day
temperature
Zone
"Zone T Day"
5
0
1
Setting night
temperature
Zona
"Zone T Night"
5
0
2
Setting fixed tem-
perature Central
Heating
"FIX Temp."
range
Note
from 10 to 0
19
(°C )
only active
when the
BUS device is
from 10 to 0
16
connected
(°C )
from 0 to 8
70
only active with
(°C)
thermoregulation set
at fixed temperature
from 10 to 0
19
(°C )
only active
when the
BUS device is
from 10 to 0
16
connected
(°C )
from 0 to 8
70
only active with
(°C)
thermoregulation set
at fixed temperature
Setting day and night temperatures for heating zone
If the boiler Genus is connected to a bus device (e.g. remote control
CLIMA MANAGER), the desired ambient temperature can be set for
day and night according to the schedule programme entered.
In central heating mode, the ignition and operation of the boiler
are used to reach and maintain set temperatures.
Setting day temperature
"Zone1 T Day"
To set day temperature , proceed as follows:
-
press the M
/
button, the display will flash
enu
ok
-
turn the CH knob
Parameters"
-
press the M
/o
button to access the sub-menu, the display
enu
k
will flash
- "Setpoints"
00
-
press the M
/o
button to access the parameters, the display
enu
k
will flash
400
- "Zone1 T Day"
-
press the M
/
button to modify the parameter;
enu
ok
-
turn the CH knob
to select the new temperature;
-
press the M
/o
button to confirm
enu
k
-
press the e
button to restore the normal display screen.
sc
To set the day temperature - heating zone (if present) proceed as
Heating Zone 1 selecting menu 5.
bar
Setting night temperature
"Zone1 T Night"
To set the night temperature , proceed as follows:
-
press the M
/
button, the display will flash
enu
ok
-
turn the CH knob
Parameters"
-
press the M
/o
button to access the sub-menu, the display
enu
k
will flash
00
- "Setpoints"
-
press the M
/o
button to access the parameters, the display
enu
k
will flash
400
- turn the encoder
to select the parameter
- "Zone1 T Night"
-
press the M
/
button to modify the parameter;
enu
ok
-
turn the CH knob
to select the new temperature;
-
press the M
/o
button to confirm
enu
k
-
press the e
button to restore the normal display screen.
sc
To set the night temperature - heating zone (if present) proceed
as Heating Zone 1, selecting menu 5.
bar
User's manual
000
to select the
menu400
Zona 1TGiorno
Zone1 T Day
000
to select the
menu400
401
Zone1 T Night
Zona 1TNotte
- "Zone1
- "Zone1
11