- ページ 10
ホームオートメーション Aeotec ZWA042のPDF マニュアルをオンラインで閲覧またはダウンロードできます。Aeotec ZWA042 11 ページ。 Outdoor smart plug
Configuration Parameters
Number
Name
Information
0 1
Reaction of led
Parameter setting to change the reaction of LED setting.
02
Night led on time
Night Light ON time.
03
Night led off time
Night Light OFF time.
Indicator play
04
Setting indicator play duration.
duration
05
Indicator speed
Select indicator flash speed.
07
Control turn off
Prevents the plug from being turned off via its button.
Restore status
08
after power
Action in case of power out.
failure
Determines if alarms are enabled in Switch, and what
30
Alarm setting
Switch will react to which alarms.
Alarm response in
Enabled by (Alarm settings), and determines what the
31
device
switch does in the case an alarm is triggered.
ZWA042 User Manual
Read
Format / Size
Altering
Advanced
Only
1 byte unsigned
NO
NO
NO
integer
4 bytes unsigned
NO
NO
NO
integer
4 bytes unsigned
NO
NO
NO
integer
1 byte unsigned
NO
NO
NO
integer
1 byte unsigned
NO
NO
NO
integer
1 byte unsigned
NO
NO
NO
integer
1 byte unsigned
NO
NO
NO
integer
1 byte unsigned
NO
NO
NO
integer
1 byte unsigned
NO
NO
NO
integer
MIN
MAX
Default
Value Description
0 - Disable LED completely
1 - Turn on between particular times only (Night Light Mode)
0
4
2
2 - Display ON/OFF status
3 - Display the reverse state of ON/OFF status
4 - Display always ON state
Value setting =0xRRHHMMSS
RR = reserved
0x00240
HH = Hours
0
0x00180000
000
MM = Minutes
SS = Seconds
● Default = 0x00180000 (6pm)
Value setting =0xRRHHMMSS
RR = reserved
0x00240
HH = Hours
0
0x00060000
000
MM = Minutes
SS = Seconds
● Default = 0x00060000 (6am)
0 - indicates that it is not blinking
1- 255 will set the duration and start the blinking process
0
255
0
This sets the timeframe of blinking in seconds
Once the duration ends, the blinking will stop and will set its configuration value back to 0
Sets amount of blinks per second
1
24
5
If set to 5, it should blink 5 times per second
Default = 5
0 - the plug will operate as normal and can be turned on or off
1 - the button on smart plug will be disabled for on and off commands, but still work for network
0
2
0
removal or inclusion
2 - the plug will ignore any commands to turn it off AND it'll ignore any use of the button (but the
button will still work for network removal or inclusion)
0 - last status
0
2
0
1 - power on
2 - power off
0 - Disable all alarm settings
1 - smoke alarm
2 - CO alarm
4 - CO2 alarm
0
255
0
8 - Heat alarm
16 - Water alarm
32 - Access Control (DW Sensor open)
64 - Home Security (intrusion)
128 - Yellow
0 - disable, no reaction to alarm settings
1 - Switch is ON
...
2 - Switch is OFF
0
255
0
...
3 - 255: Sets rate at which Switch turns ON and OFF in seconds (ie. if set to 3, then switch will turn ON
in 0.3 seconds, and then turn OFF in 0.3 seconds in a cycle until user disables the alarm manually, if set
to 255, then it will cycle every 25.5 seconds)