ホームオートメーション Aeotec ZWA042のPDF マニュアルをオンラインで閲覧またはダウンロードできます。Aeotec ZWA042 11 ページ。 Outdoor smart plug
Button & Indicator Function Description
Button Definition
ITEMS
Action (time unit: second)
1
Tap one time [0.04,1]
2
Tap two times [0.04, 1]
4
Press and hold [5,10]
5
Press and hold [15,20]
6
Press and hold [22,∞)
LED indicator
Action
Press down Action Button
Tap one time
Solid Yellow Status
[0.04,1]
Secure / Non-secure network: Purple
Tap twotimes
Led keeps ON for 2 seconds and then
OFF.
Press and hold
LED should revert back to LED state if
[1,1]
paired or unpaired.
Press and hold
Solid orange status
[2,5]
Press and hold
Solid cyan status
[5,9]
Press and hold
Solid red led status
[9,15]
red color will blink on and off at a rate
Press and hold
of 200ms for 2 seconds and then should
[15,20]
pulse blue color based on unpair status.
Description
Out of network: Z-Wave network inclusion(ADD) (send out NIF of full functionality )
In network: N/A
In/Out of network: controls/toggles output on/off
Out of network: N/A
In network: Z-Wave network exclusion(REMOVE: Send out NIF) .
Enter RF power level test mode
Reset to factory default setting and then send Device Reset Locally to primary controller.
Note: Please use this procedure only when the network primary controller is missing or otherwise inoperable.
If still do not release the button, nothing will happen. LED should continue to pulse blue for unpaired state.
Release Action Button
Turns on a solid yellow status, If a new node id is assigned to this device, the yellow LED will keep solid until whole network processing is complete (or
entering. If successful, the LED will flash white -> green -> white -> green (at a rate of 250ms per each color change) for 2 seconds. After 2 seconds have
finished, use typical paired status LED indicators for ON/OFF status from parameter #1. Control function: controls/toggles output on/off
If the exclusion is successful, the Led will pulse a blue LED color based on unpair status.
LED should revert back to LED state if paired or unpaired.
cyan led will remain solid upon releasing the button, which indicates the network quality is entering diagnosing, the led will be light up with 1 of 3 colors
for 2 seconds after the diagnosing is complete. (Red = bad, Yellow = ok, Green = Good)
Reset to factory default setting and then send Device Reset Locally to primary controller
Note: Please use this procedure only when the network primary controller is missing or otherwise inoperable.
ZWA042 User Manual